摘要
A flow injection analysis of Ca2+ and Mg2+ using indirect potentiometric detection in natural waters is proposed, where Ca2+ or Mg2+ are injected into a buffer carrier containing phosphate, resulting in the formation of Ca-3(PO4)(2) or Mg-3(PO4)(2). The consequent reduction in free phosphate in the carrier solution is detected using a metallic cobalt wire electrode. Indirect electrode response was used and the experimental conditions affecting electrode response were optimized. Responses were linear in the concentration range 5 x 10(-4) to 5 x 10(-3) M with a detection limit of 1 x 10(-5) M in 20 mM phosphate buffer at pH 8.0. The relative standard derivation at 1 mM of Ca2+ and Mg2+ were 3.9 and 3.7% (n = 10), respectively. EGTA and 8-hydroxyquinoline were used as the masking agents for Ca2+ and Mg2+, respectively. Concentrations of Ca2+ and Mg2+ in natural waters were successfully determined by the proposed method. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:779 / 786
页数:8
相关论文
共 24 条
[1]   INDIRECT POTENTIOMETRIC DETERMINATION OF METAL-IONS BY FLOW-INJECTION ANALYSIS WITH A COPPER ELECTRODE [J].
ALEXANDER, PW ;
TROJANOWICZ, M ;
HADDAD, PR .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (04) :309-320
[2]  
BASSON WD, 1981, ANALYST, V103, P361
[3]   Simultaneous spectrophotometric determination of calcium and magnesium in mineral waters by means of multivariate partial least-squares regression [J].
Blasco, F ;
MedinaHernandez, MJ ;
Sagrado, S ;
Fernandez, FM .
ANALYST, 1997, 122 (07) :639-643
[4]   Flow-injection potentiometric detection of phosphates using a metallic cobalt wire ion-selective electrode [J].
Chen, ZL ;
DeMarco, R ;
Alexander, PW .
ANALYTICAL COMMUNICATIONS, 1997, 34 (03) :93-95
[5]  
CLEMENT RE, 1993, ANAL CHEM, V65, pR85, DOI [10.1021/ac00060a007, 10.1021/ac00108a012]
[6]   FLOW-INJECTION DETERMINATION OF PHOSPHATE WITH A CADMIUM ION-SELECTIVE ELECTRODE [J].
DAVEY, DE ;
MULCAHY, DE ;
OCONNELL, GR .
TALANTA, 1990, 37 (07) :683-687
[7]  
Dean J., 1995, Analytical Chemistry Handbook
[8]   Extension of the dynamic range of flame atomic absorption spectrometry using flow injection analysis with variable-volume dilution chambers [J].
ElAzouzi, H ;
PerezJordan, MY ;
Salvador, A ;
delaGuardia, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1747-1752
[9]   FLOW-INJECTION SYSTEMS WITH A STREAM SPLITTING AND A DIALYSIS UNIT FOR THE SOIL ANALYSIS OF SODIUM AND POTASSIUM BY FLAME EMISSION-SPECTROMETRY, AND CALCIUM AND MAGNESIUM BY ATOMIC-ABSORPTION SPECTROPHOTOMETRY [J].
FERREIRA, AMR ;
RANGEL, AOSS ;
LIMA, JLFC .
COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 1995, 26 (1-2) :183-195
[10]   NONLINEAR CALIBRATION OF ION-SELECTIVE ELECTRODE ARRAYS FOR FLOW-INJECTION ANALYSIS [J].
FORSTER, RJ ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (15) :1721-1728