High-resolution contrast-enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival: Diagnostic accuracy and interobserver variability

被引:15
作者
Butz, B [1 ]
Dorenbeck, U
Borisch, I
Zorger, N
Lenhart, M
Feuerbach, S
Link, J
机构
[1] Univ Regensburg Hosp, Dept Radiol, D-93042 Regensburg, Germany
[2] Univ Homburg Hosp, Dept Neuroradiol, Homburg, Germany
[3] Spitalreg St Gallen, Dept Radiol, St Gallen, Switzerland
关键词
angiography; elliptic centric view ordering; magnetic resonance imaging; supra-aortic arteries;
D O I
10.1080/02841850410003699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiograpby (CE-MRA) of the supra-aortic arteries using the CareBolus technique. Digital subtraction angiography was the standard of reference. Material and Methods: Fifty consecutive patients with suspected internal carotid artery stenosis underwent CE-MRA and digital subtraction angiography. CE-MRA was performed on a 1.5-T superconducting scanner with the CareBolus technique. CareBolus combines a nearly real-time 2D-FLASH (fast low angle shot) sequence for fluoroscopic triggering and a high-resolution 3D-FLASH with elliptical centric view order for the angiographic Pulse sequence (6.0/2.16 ms [TR/TE], 30degrees flip angle, 30.98 s acquisition time, 0.88 mm effective (interpolated) partition thickness and a 160 x 512 matrix). Intra-arterial digital subtraction angiography and CE-MRA studies were evaluated independently by four blinded readers. Internal carotid artery stenoses were graded according to the NASCET criteria. Results: CE-MRA had an accuracy of 92.53%, a sensitivity of 95.64%, and a specificity of 90.39% for the identification of carotid artery stenoses greater than or equal to 70% (grade 3). Image quality for suppression of stationary tissue and venous contrast was good, but was reduced in five cases due to patient motion. Conclusion: The CareBolus technique is a useful non-invasive method for high-resolution imaging of the supra-aortic vessels because of its easy application and high sensitivity and specificity. Limitations can occur in non-compliant patients due to motion artifacts during the measurement time.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 22 条
[1]   Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis [J].
Barnett, HJM ;
Taylor, W ;
Eliasziw, M ;
Fox, AJ ;
Ferguson, GG ;
Haynes, RB ;
Rankin, RN ;
Clagett, GP ;
Hachinski, VC ;
Sackett, DL ;
Thorpe, KE ;
Meldrum, HE ;
Spence, JD .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (20) :1415-1425
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   3D gadolinium-enhanced MR angiography of the carotid arteries [J].
Cloft, HJ ;
Murphy, KJ ;
Prince, MR ;
Brunberg, JA .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :593-600
[4]   Contrast-enhanced carotid MR angiography with commercially available triggering mechanisms and elliptic centric phase encoding [J].
De Marco, JK ;
Schonfeld, S ;
Keller, I ;
Bernstein, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :221-227
[5]   Gadolinium-enhanced MR angiography of the carotid arteries [J].
Enochs, WS ;
Ackerman, RH ;
Kaufman, JA ;
Candia, M .
JOURNAL OF NEUROIMAGING, 1998, 8 (04) :185-190
[6]   Fluoroscopically triggered contrast-enhanced 3D MR DSA and 3D time-of-flight turbo MRA of the carotid arteries: first clinical experiences in correlation with ultrasound, x-ray angiography, and endarterectomy findings [J].
Fellner, FA ;
Fellner, C ;
Wutke, R ;
Lang, W ;
Laub, G ;
Schmidt, M ;
Janka, R ;
Denzel, C ;
Bautz, W .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :575-585
[7]   HOW TO MEASURE CAROTID STENOSIS [J].
FOX, AJ .
RADIOLOGY, 1993, 186 (02) :316-318
[8]   CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY [J].
HEISERMAN, JE ;
DRAYER, BP ;
FRAM, EK ;
KELLER, PJ ;
BIRD, CR ;
HODAK, JA ;
FLOM, RA .
RADIOLOGY, 1992, 182 (03) :761-768
[9]   Carotid arteries: Maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering [J].
Huston, J ;
Fain, SB ;
Riederer, SJ ;
Wilman, AH ;
Bernstein, MA ;
Busse, RF .
RADIOLOGY, 1999, 211 (01) :265-273
[10]  
Huston J, 2001, RADIOLOGY, V218, P138