Tomography of integrated circuit interconnect with an electromigration void

被引:25
作者
Levine, ZH [1 ]
Kalukin, AR
Kuhn, M
Frigo, SP
McNulty, I
Retsch, CC
Wang, YX
Arp, U
Lucatorto, TB
Ravel, BD
Tarrio, C
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[2] Rensselaer Polytech Inst, Troy, NY 12180 USA
[3] Intel Corp RA1 329, Hillsboro, OR 97124 USA
[4] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
D O I
10.1063/1.373095
中图分类号
O59 [应用物理学];
学科分类号
摘要
An integrated circuit interconnect was subject to accelerated-life test conditions to induce an electromigration void. The silicon substrate was removed, leaving only the interconnect test structure encased in silica. We imaged the sample with 1750 eV photons using the 2-ID-B scanning transmission x-ray microscope at the Advanced Photon Source, a third-generation synchrotron facility. Fourteen views through the sample were obtained over a 170 degrees range of angles (with a 40 degrees gap) about a single rotation axis. Two sampled regions were selected for three-dimensional reconstruction: one of the ragged end of a wire depleted by the void, the other of the adjacent interlevel connection (or "via"). We applied two reconstruction techniques: the simultaneous iterative reconstruction technique and a Bayesian reconstruction technique, the generalized Gaussian Markov random field method. The stated uncertainties are total, with one standard deviation, which resolved the sample to 200 +/- 70 and 140 +/- 30 nm, respectively. The tungsten via is distinguished from the aluminum wire by higher absorption. Within the void, the aluminum is entirely depleted from under the tungsten via. The reconstructed data show the applicability of this technique to three-dimensional imaging of buried defects in submicrometer structures relevant to the microelectronics industry. (C) 2000 American Institute of Physics. [S0021-8979(00)00509-0].
引用
收藏
页码:4483 / 4488
页数:6
相关论文
共 18 条
[1]  
BORN M, 1975, PRINCIPLES OPTICS, P415
[2]   A generalized Gaussian image model for edge-preserving MAP estimation [J].
Bournan, Charles ;
Sauer, Ken .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1993, 2 (03) :296-310
[3]   3-DIMENSIONAL X-RAY MICROTOMOGRAPHY [J].
FLANNERY, BP ;
DECKMAN, HW ;
ROBERGE, WG ;
DAMICO, KL .
SCIENCE, 1987, 237 (4821) :1439-1444
[4]   ULTRAHIGH-RESOLUTION X-RAY TOMOGRAPHY [J].
HADDAD, WS ;
MCNULTY, I ;
TREBES, JE ;
ANDERSON, EH ;
LEVESQUE, RA ;
YANG, L .
SCIENCE, 1994, 266 (5188) :1213-1215
[5]   BAYESIAN-APPROACH TO LIMITED-ANGLE RECONSTRUCTION IN COMPUTED-TOMOGRAPHY [J].
HANSON, KM ;
WECKSUNG, GW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1983, 73 (11) :1501-1509
[6]   ELECTROMIGRATION AND STRESS-INDUCED VOIDING IN FINE AL AND AL-ALLOY THIN-FILM LINES [J].
HU, CK ;
RODBELL, KP ;
SULLIVAN, TD ;
LEE, KY ;
BOULDIN, DP .
IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1995, 39 (04) :465-497
[7]  
*ICE LAB, 1998, AMDS K6 MICR POST
[8]   Methods to remove distortion artifacts in scanned projections [J].
Kalukin, AR ;
Levine, ZH ;
Tarrio, C ;
Frigo, SP ;
McNulty, I ;
Wang, Y ;
Retsch, CC ;
Kuhn, M ;
Winn, B .
DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 :237-245
[9]  
KALUKIN AR, IN PRESS J RES NATL
[10]   SOFT-X-RAY MICROSCOPES AND THEIR BIOLOGICAL APPLICATIONS [J].
KIRZ, J ;
JACOBSEN, C ;
HOWELLS, M .
QUARTERLY REVIEWS OF BIOPHYSICS, 1995, 28 (01) :33-130