Near-infrared fluorescence contrast-enhanced imaging with intensified charge-coupled device homodyne detection: measurement precision and accuracy

被引:54
作者
Thompson, AB
Sevick-Muraca, EM [1 ]
机构
[1] Texas A&M Univ, Dept Chem, Zachry Engn Ctr 337, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Chem Engn, Zachry Engn Ctr 337, College Stn, TX 77843 USA
关键词
frequency-domain photon migration; intensified charge-coupled device; fluorescent contrast agent;
D O I
10.1117/1.1528205
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence frequency-domain photon migration (FDPM) through tissue refers to the propagation of intensity-modulated fluorescent light that originates from tissue-laden fluorophores following illumination with an intensity-modulated excitation light source. FDPM measurements of modulation amplitude and phase are ultimately employed in an inversion algorithm for tomographic reconstruction of interior optical and fluorescent property maps that delineate disease enhanced with fluorescent contrast agent. Because the inverse problem is underdetermined, measurement precision and accuracy crucially impact its solution. Reported here are the precision and accuracy of FDPM measurements acquired using an intensified CCD homodyne detection system. By introducing 32 phase delays between the oscillators used to modulate the intensifier gain and light source intensity at 100 MHz, mean precision is maximized at +/- 0.46% and +/- 0.26 deg for measurements of modulation amplitude and phase, respectively. Measurement precision improves when the number of phase delays increases. Measurements of fluorescence modulation amplitude and phase, acquired from the surface of a tissue phantom at distances ranging between 0.71 and 3.6 cm from an incident excitation point source, exhibit a mean accuracy of 170% and 1.9 deg, respectively. Measurement accuracy deteriorates with increasing distance from the point source, but for distances up to 1.0 cm from the point source, measurements of fluorescence modulation amplitude and phase exhibit a mean accuracy of 5.4% and 0.30 deg, respectively. (C) 2003 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:111 / 120
页数:10
相关论文
共 44 条
[1]   Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging [J].
Achilefu, S ;
Dorshow, RB ;
Bugaj, JE ;
Rajagopalan, R .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :479-485
[2]   Tumor detection and visualization using cyanine fluorochrome-labeled antibodies [J].
Ballou, B ;
Fisher, GW ;
Hakala, TR ;
Farkas, DL .
BIOTECHNOLOGY PROGRESS, 1997, 13 (05) :649-658
[3]  
Becker A, 2000, PHOTOCHEM PHOTOBIOL, V72, P234, DOI 10.1562/0031-8655(2000)072<0234:MCAFOI>2.0.CO
[4]  
2
[5]   Fluorescence lifetime imaging of experimental tumors in hematoporphyrin derivative-sensitized mice [J].
Cubeddu, R ;
Canti, G ;
Pifferi, A ;
Taroni, P ;
Valentini, G .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1997, 66 (02) :229-236
[6]  
Duderstadt J. J., 1976, NUCL REACTOR ANAL
[7]   Biomedical optical tomography using dynamic parameterization and Bayesian conditioning on photon migration measurements [J].
Eppstein, MJ ;
Dougherty, DE ;
Troy, TL ;
Sevick-Muraca, EM .
APPLIED OPTICS, 1999, 38 (10) :2138-2150
[8]   Three-dimensional, Bayesian image reconstruction from sparse and noisy data sets: Near-infrared fluorescence tomography [J].
Eppstein, MJ ;
Hawrysz, DJ ;
Godavarty, A ;
Sevick-Muraca, EM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (15) :9619-9624
[9]   Three-dimensional Bayesian optical image reconstruction with domain decomposition [J].
Eppstein, MJ ;
Dougherty, DE ;
Hawrysz, DJ ;
Sevick-Muraca, EM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (03) :147-163
[10]   Role and evaluation of mammography and other imaging methods for breast cancer detection, diagnosis, and staging [J].
Feig, SA .