Convection warmers - a possible source of contamination in laminar airflow operating theatres?

被引:43
作者
Tumia, N [1 ]
Ashcroft, GP [1 ]
机构
[1] Univ Aberdeen, Sch Med, Dept Orthopaed, Aberdeen AB9 2ZB, Scotland
关键词
convection heaters; operating theatre; ultra-clean air; infection;
D O I
10.1053/jhin.2002.1297
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This work results from concerns that forced-air convection heaters applied to patients in the operating theatre might interfere with ultra-clean ventilation system and thus be a potential source of wound contamination. Air samples were taken in the operative field and the bacterial load calculated by estimating the number of colony forming units per cubic metre of air (cfu/m(3)). Six tests were carried out, two in empty theatres and four during standard orthopaedic operating lists. Differences were seen between empty theatres and those standing empty for short periods during busy operating lists. Increases were seen on entry to theatre of staff and patients with the convection heaters off. A further small rise was seen after the convection heaters were turned on when applied to patients. This study showed that use of warm air convection heaters on patients produced a small increase in the number of colony forming units in ultra-clean air theatres but the levels were unlikely to have clinical significance. By far the greatest effect on numbers was movement and presence of the patient and theatre staff in the theatre.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 7 条
[1]   AIR CONTAMINATION DURING HIP AND KNEE ARTHROPLASTIES - HORIZONTAL LAMINAR-FLOW RANDOMIZED VS CONVENTIONAL VENTILATION [J].
AHL, T ;
DALEN, N ;
JORBECK, H ;
HOBORN, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (01) :17-20
[2]  
Andersen Bjorg Marit, 1998, Tidsskrift for den Norske Laegeforening, V118, P3148
[3]   Convection warmers - not just hot air [J].
Avidan, MS ;
Jones, N ;
Ing, R ;
Khoosal, M ;
Lundgren, C ;
Morrell, DF .
ANAESTHESIA, 1997, 52 (11) :1073-1076
[4]   PREVENTION OF HYPOTHERMIA DURING HIP-SURGERY - EFFECT OF PASSIVE COMPARED WITH ACTIVE SKIN SURFACE WARMING [J].
BENNETT, J ;
RAMACHANDRA, V ;
WEBSTER, J ;
CARLI, F .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (02) :180-183
[5]  
Howorth F H, 1986, Hosp Eng, V40, P17
[6]   Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization [J].
Kurz, A ;
Sessler, DI ;
Lenhardt, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (19) :1209-1215
[7]   A BACTERIOLOGICALLY OCCLUSIVE CLOTHING SYSTEM FOR USE IN THE OPERATING-ROOM [J].
WHYTE, W ;
BAILEY, PV ;
HAMBLEN, DL ;
FISHER, WD ;
KELLY, IG .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (04) :502-506