Identification and quantification of five macrolide antibiotics in several tissues, eggs and milk by liquid chromatography-electrospray tandem mass spectrometry

被引:129
作者
Dubois, M [1 ]
Fluchard, D [1 ]
Sior, E [1 ]
Delahaut, P [1 ]
机构
[1] CER, Lab Hormonol, B-6900 Marloie, Belgium
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 753卷 / 02期
关键词
tylosin; tilmicosin; spiramycin; josamycin; erythromycin;
D O I
10.1016/S0378-4347(00)00542-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present an electrospray high-performance liquid chromatographic tandem mass spectrometric (HPLC-MS-MS) method capable of determining in several tissues (muscle, kidney, liver), eggs and milk the following five macrolides: tylosin, tilmicosin, spiramycin, josamycin, erythromycin. Roxithromycin was used as an internal standard. The method uses extraction in a Tris buffer at pH 10.5, followed by protein precipitation with sodium tungstate and clean-up on an Oasis solid-phase extraction column. The HPLC separation was performed on a Purospher C-18 column (125x3 mm LD.) protected by a guard column, with a gradient of aqueous 0.1 M ammonium acetate-acetonitrile as the mobile phase at a how-rate of 0.7 ml min(-1). Protonated molecules served as precursor ions for electrospray ionisation in the positive ion mode and four product ions were chosen for each analyte for multiple reaction monitoring (MRM). A validation study was conducted to confirm the five macrolides by MRM HPLC-MS-MS analysis of a negative control and fortified samples. All of the samples analysed were confirmed with four ions. The ion ratio reproducibility limit ranged from 2.4 to 15%. All compounds could be detected and quantified at half-maximum residue limits (MRLs). The method is specific, quantitative and reproducible enough to conform to European Union recommendations within the concentration range 0.5 MRL-2 MRL (accuracy: 80 to 110%, relative standard deviation: 2 to 13%). This whole method allows extraction and analysis of up to 50 samples per day. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 202
页数:14
相关论文
共 23 条
  • [1] [Anonymous], OFF METH RES SUBST L
  • [2] *AOAC INT, 1995, OFF METH AN AOAC INT
  • [3] CHAN W, 1994, J AOAC INT, V77, P331
  • [4] Delepine B, 1996, J AOAC INT, V79, P397
  • [5] IDENTIFICATION OF TYLOSIN IN BOVINE MUSCLE AT THE MAXIMUM RESIDUE LIMIT LEVEL BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY, USING A PARTICLE-BEAM INTERFACE
    DELEPINE, B
    HURTAUD, D
    SANDERS, P
    [J]. ANALYST, 1994, 119 (12) : 2717 - 2721
  • [6] PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH NEGATIVE-ION CHEMICAL IONIZATION FOR THE CONFIRMATION OF IVERMECTIN RESIDUE IN BOVINE-MILK AND LIVER
    HELLER, DN
    SCHENCK, FJ
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (03) : 184 - 193
  • [7] Simultaneous determination of five macrolide antibiotics in meat by high-performance liquid chromatography
    Horie, M
    Saito, K
    Ishii, R
    Yoshida, T
    Haramaki, Y
    Nakazawa, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 295 - 302
  • [8] DETERMINATION OF MIROSAMICIN IN ANIMAL-TISSUES BY HIGHPERFORMANCE LIQUID-CHROMATOGRAPHY
    HORIE, M
    SAITO, K
    NOSE, N
    OKA, H
    NAKAZAWA, H
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 655 (01): : 47 - 52
  • [9] HOWS MEP, 2000, P EUR 4 C VELDH 8 10, P581
  • [10] DETERMINATION OF ERYTHROMYCIN-A BY LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL DETECTION, WITH APPLICATION TO SALMON TISSUE
    JANECEK, M
    QUILLIAM, MA
    BAILEY, MR
    NORTH, DH
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 619 (01): : 63 - 69