Mixed hemimicelles solid-phase extraction based on cetyltrimethylammonium bromide-coated nano-magnets Fe3O4 for the determination of chlorophenols in environmental water samples coupled with liquid chromatography/spectrophotometry detection

被引:201
作者
Li, Jidong [1 ,2 ]
Zhao, Xiaoli [1 ]
Shi, Yali [1 ]
Cai, Yaqi [1 ]
Mou, Shifen [1 ]
Jiang, Guibin [1 ]
机构
[1] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, State Key Lab Environm Chem & Ecotoxicol, Beijing 100085, Peoples R China
[2] Gen Res Inst NonFerrous Met, Beijing 100088, Peoples R China
基金
中国国家自然科学基金;
关键词
nanoparticles; Fe3O4; magnetism; mixed hemimicelles; solid-phase extraction; chlorophenols;
D O I
10.1016/j.chroma.2007.12.028
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mixed hemimicelles solid-phase extraction (SPE) based on cetyltrimethylammonium bromide (CTAB)-coated nano-magnets Fe3O4 was investigated for the preconcentration of four chlorophenols (CPs) in environmental water samples prior to HPLC-spectrophotometry determination in this paper. By the rapid isolating (about 5 min) of Fe3O4 nanoparticles (NPs) through placing a Nd-Fe-B strong magnet on the bottom of beaker, the time-consuming preconcentration process of loading large volume sample in conversional SPE method with a column can be avoided. The unique properties of Fe3O4 NPs such as high surface area and strong magnetism were utilized adequately in the SPE process. This novel separation method produced a high preconcentration rate and factor. A comprehensive study of the adsorption conditions such as the Fe3O4 NPs zeta-potential, CTAB added amounts, pH value, standing time and maximal extraction volume was also presented. Under optimized conditions, four analytes of 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (TCP) and pentachlorophenol (PCP) were quantitatively extracted. The method was then used to determine four CPs in five real environmental water samples. High concentration factors (700) were achieved for each of the analytes, with observed detection limits ranging between 0.11 and 0.15 mu g L-1. The accuracy of method was evaluated by recovery measurements on spiked samples. Good recovery results (83-98%) with satisfactory relative standard deviation (RSD) were achieved. It is important to note that satisfactory preconcentration factors and extraction recoveries for the four CPs were obtained with only a little amount of Fe3O4 NPs (0.1 g) and CTAB (60 mg). To the best of our knowledge, this was the first time a mixed hemimicelles SPE method based on Fe3O4 NPs magnetic separation had been used for the pretreatment of environmental water samples. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 43 条
  • [1] Andra W., 1998, MAGNETISM MED HDB
  • [2] DETERMINATION OF PHENOLIC-COMPOUNDS IN SURFACE-WATER USING ONLINE LIQUID-CHROMATOGRAPHIC PRECOLUMN-BASED COLUMN-SWITCHING TECHNIQUES
    BROUWER, ER
    BRINKMAN, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (02) : 223 - 231
  • [3] Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol a, 4-n-nonylphenol, and 4-tert-octylphenol
    Cai, YQ
    Jiang, GB
    Liu, JF
    Zhou, QX
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2517 - 2521
  • [4] Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples
    Cai, YQ
    Cai, YE
    Mou, SF
    Lu, YQ
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (02) : 245 - 247
  • [5] Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography
    Cai, YQ
    Jiang, GB
    Liu, JF
    Zhou, QX
    [J]. ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) : 149 - 156
  • [6] Determination of non-ionic polyethoxylated surfactants in wastewater and river water by mixed hemimicelle extraction and liquid chromatography-ion trap mass spectrometry
    Cantero, M
    Rubio, S
    Pérez-Bendito, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1067 (1-2) : 161 - 170
  • [7] Size-dependent magnetic properties of MnFe2O4 fine particles synthesized by coprecipitation
    Chen, JP
    Sorensen, CM
    Klabunde, KJ
    Hadjipanayis, GC
    Devlin, E
    Kostikas, A
    [J]. PHYSICAL REVIEW B, 1996, 54 (13): : 9288 - 9296
  • [8] ENHANCED FLUORESCENCE DETECTION OF DANSYL DERIVATIVES OF PHENOLIC-COMPOUNDS USING A POSTCOLUMN PHOTOCHEMICAL REACTOR AND APPLICATION TO CHLOROPHENOLS IN RIVER WATER
    DERUITER, C
    BOHLE, JF
    DEJONG, GJ
    BRINKMAN, UAT
    FREI, RW
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (07) : 666 - 670
  • [9] Adsorption of alkyltrimethylammonium bromides on negatively charged alumina
    Fan, AX
    Somasundaran, P
    Turro, NJ
    [J]. LANGMUIR, 1997, 13 (03) : 506 - 510
  • [10] Determination of phenols in water by on-line solid-phase disk extraction and liquid chromatography with electrochemical detection
    Jauregui, O