Towards more complete specifications for acceptable analytical performance - a plea for error grid analysis

被引:7
作者
Krouwer, Jan S. [1 ]
Cembrowski, George S. [2 ]
机构
[1] Krouwer Consulting, Sherborn, MA 01770 USA
[2] Hlth Sci Ctr, Walter C MacKenzie Ctr, Alberta Hlth Serv, Edmonton, AB, Canada
关键词
error grids; FMEA; FRACAS; specifications; total error; LABORATORY MEDICINE; EDUCATION-PROGRAM; PATIENT SAFETY; RECOMMENDATIONS; QUALITY;
D O I
10.1515/CCLM.2011.610
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
We examine limitations of common analytical performance specifications for quantitative assays. Specifications can be either clinical or regulatory. Problems with current specifications include specifying limits for only 95% of the results, having only one set of limits that demarcate no harm from minor harm, using incomplete models for total error, not accounting for the potential of user error, and not supplying sufficient protocol requirements. Error grids are recommended to address these problems as error grids account for 100% of the data and stratify errors into different severity categories. Total error estimation from a method comparison can be used to estimate the inner region of an error grid, but the outer region needs to be addressed using risk management techniques. The risk management steps, foreign to many in laboratory medicine, are outlined.
引用
收藏
页码:1127 / 1130
页数:4
相关论文
共 24 条
[1]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[2]  
[Anonymous], 2003, ISO 15197
[3]  
BACHORIK PS, 1995, CLIN CHEM, V41, P1414
[4]  
Bonini P, 2002, CLIN CHEM, V48, P691
[5]   Clinical Governance: from clinical risk management to continuous quality improvement [J].
Chiozza, Maria Laura ;
Plebani, Mario .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (06) :694-698
[6]   FMEA: A model for reducing medical errors [J].
Chiozza, Maria Laura ;
Ponzetti, Clemente .
CLINICA CHIMICA ACTA, 2009, 404 (01) :75-78
[7]  
Clinical and Laboratory Standards Institute (CLSI), 2003, EP21A CLSI
[8]  
*CLSI, 2009, EP27P CLSI
[9]  
CLSI, 2009, EP18A2 CLSI
[10]   PREVENTABLE ANESTHESIA MISHAPS - STUDY OF HUMAN-FACTORS [J].
COOPER, JB ;
MCPEEK, B ;
LONG, CD ;
NEWBOWER, RS .
ANESTHESIOLOGY, 1978, 49 (06) :399-406