Application of independent component analysis to 1H MR spectroscopic imaging exams of brain tumours

被引:34
作者
de Edelenyi, FS [1 ]
Simonetti, AW [1 ]
Postma, G [1 ]
Huo, R [1 ]
Buydens, LMC [1 ]
机构
[1] Radboud Univ Nijmegen, Dept Analyt Chem, Nijmegen, Netherlands
关键词
MRS; brain tumours; independent component analysis; MCR;
D O I
10.1016/j.aca.2005.04.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The low spatial resolution of clinical H-1 MRSI leads to partial volume effects. To overcome this problem, we applied independent component analysis (ICA) on a set of H-1 MRSI exams of brain turnours. With this method, tissue types that yield statistically independent spectra can be separated. Up to three components, corresponding to necrosis, tumoral tissue and healthy tissue have been detected inside turnours. In nonagressive turnours, the "necrotic" component was absent, confirming that only agressive turnours exhibit high levels of lipids. In conclusion, the ICA algorithm allows to find useful hidden components in turnours. The reliability and robustness of the results have also been investigated by means of bootstrapping combined with unsupervised clustering. A comparison of ICA with a method of curve resolution, MCR-ALS, has also been performed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 46
页数:11
相关论文
共 20 条
[1]  
[Anonymous], 1999, P INT WORKSH IND COM
[2]   Independent component representations for face recognition [J].
Bartlett, MS ;
Lades, HM ;
Sejnowski, TJ .
HUMAN VISION AND ELECTRONIC IMAGING III, 1998, 3299 :528-539
[3]   RESOLUTION ENHANCEMENT OF PROTEIN PMR SPECTRA USING DIFFERENCE BETWEEN A BROADENED AND A NORMAL SPECTRUM [J].
CAMPBELL, ID ;
DOBSON, CM ;
WILLIAMS, RJP ;
XAVIER, AV .
JOURNAL OF MAGNETIC RESONANCE, 1973, 11 (02) :172-181
[4]   A new approach for analyzing proton magnetic resonance spectroscopic images of brain tumors:: nosologic images [J].
De Edeleny, FS ;
Rubin, C ;
Estève, F ;
Grand, S ;
Décorps, M ;
Lefournier, V ;
Le Bas, JF ;
Rémy, C .
NATURE MEDICINE, 2000, 6 (11) :1287-1289
[5]  
Hagberg G, 1998, NMR BIOMED, V11, P148, DOI 10.1002/(SICI)1099-1492(199806/08)11:4/5<148::AID-NBM511>3.0.CO
[6]  
2-4
[7]   ICASSO:: Software for investigating the reliability of ICA estimates by clustering and visualization [J].
Himberg, J ;
Hyvärinen, A .
2003 IEEE XIII WORKSHOP ON NEURAL NETWORKS FOR SIGNAL PROCESSING - NNSP'03, 2003, :259-268
[8]   Improved DOSY NMR data processing by data enhancement and combination of multivariate curve resolution with non-linear least square fitting [J].
Huo, R ;
Wehrens, R ;
Buydens, LMC .
JOURNAL OF MAGNETIC RESONANCE, 2004, 169 (02) :257-269
[9]   Fast and robust fixed-point algorithms for independent component analysis [J].
Hyvärinen, A .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1999, 10 (03) :626-634
[10]   Independent component analysis:: algorithms and applications [J].
Hyvärinen, A ;
Oja, E .
NEURAL NETWORKS, 2000, 13 (4-5) :411-430