Effect of gravity in differential mobility analysers. A new method to determine the density and mass of aerosol particles

被引:11
作者
Le Bronec, E
Renoux, A
Boulaud, D [1 ]
Pourprix, M
机构
[1] CEA Saclay, Inst Protect & Surete Nucl, Lab Phys & Metrol Aerosols, F-91191 Gif Sur Yvette, France
[2] Univ Paris 12, Lab Phys Aerosols & Transfert Contaminat, F-94010 Creteil, France
关键词
D O I
10.1016/S0021-8502(98)00023-8
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Mobility analysers select particles according to their electrical mobility. In order to take into account the effect of gravity in these analysers, we introduce the settling velocity in equations governing the behaviour of particles. We deduce a new transfer function taking into account the effect of gravity. Based on these theoretical results, we developed a new application. By simultaneously measuring the relaxation time and the electrical mobility of aerosols, we determine their diameter, their mass and therefore their density. In order to validate this theory, we measure the mass of a latex particle (diameter between 0.1 and 2 mu m) with a radial how differential mobility analyser known under the name SMEC. The agreement between the theoretical and the experimental values is good and the uncertainty less than 5% for latex particles with a diameter greater than 0.5 mu m. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:89 / 103
页数:15
相关论文
共 14 条
[1]  
BOULAND D, 1996, J AEROSOL SCI, V27, pS307
[2]   A NEW TECHNIQUE FOR THE DETERMINATION OF THE DENSITY OF AIRBORNE PARTICULATE MATTER [J].
EMETS, EP ;
KASCHEEV, VA ;
POLUEKTOV, PP .
JOURNAL OF AEROSOL SCIENCE, 1992, 23 (01) :27-35
[3]  
Knutson E. O., 1975, Journal of Aerosol Science, V6, P453, DOI 10.1016/0021-8502(75)90061-0
[4]  
Knutson E. O., 1975, Journal of Aerosol Science, V6, P443, DOI 10.1016/0021-8502(75)90060-9
[5]   DETERMINATION OF PARTICLE-SIZE DISTRIBUTION OF ULTRA-FINE AEROSOLS USING A DIFFERENTIAL MOBILITY ANALYZER [J].
KOUSAKA, Y ;
OKUYAMA, K ;
ADACHI, M .
AEROSOL SCIENCE AND TECHNOLOGY, 1985, 4 (02) :209-225
[6]   EFFECT OF BROWNIAN DIFFUSION ON ELECTRICAL CLASSIFICATION OF ULTRAFINE AEROSOL-PARTICLES IN DIFFERENTIAL MOBILITY ANALYZER [J].
KOUSAKA, Y ;
OKUYAMA, K ;
ADACHI, M ;
MIMURA, T .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1986, 19 (05) :401-407
[7]   SUBMICRON AEROSOL STANDARD AND PRIMARY, ABSOLUTE CALIBRATION OF CONDENSATION NUCLEI COUNTER [J].
LIU, BYH ;
PUI, DYH .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1974, 47 (01) :155-171
[8]  
MESBAH B, 1994, THESIS U PARIS 12
[9]  
POURPRIX M, 1994, 4 INT AER C LOS ANG, V1, P463
[10]   THE RELATIONSHIP OF INPUT AND OUTPUT AEROSOL CHARACTERISTICS FOR AN IDEAL DIFFERENTIAL MOBILITY ANALYZER PARTICLE STANDARD [J].
REISCHL, GP .
JOURNAL OF AEROSOL SCIENCE, 1991, 22 (03) :297-312