DGT as an in situ tool for measuring radiocesium in natural waters

被引:43
作者
Murdock, C
Kelly, M [1 ]
Chang, LY
Davison, W
Zhang, H
机构
[1] Univ Lancaster, Dept Environm Sci, Lancaster LA1 4YQ, England
[2] Radman Associates, Macclesfield SK10 5JR, Cheshire, England
关键词
D O I
10.1021/es0100874
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The application of diffusive gradients in thin-films (DGT) samplers for the measurement of cesium radionuclides in solution, using an ammonium molybdophosphate (AMP) binding agent, was tested under both laboratory and field conditions. In the former they proved able to reproduce known Cs-134 concentrations (60 Bq L-1) with a high degree of accuracy and precision over periods up to similar to1 d, in freshwaters over a wide range of pH and temperature, and in saline water. In field trials in a freshwater lake receiving nuclear power station discharges, mean concentrations Of Cs-137 (47-61 mBq L-1) were measured over periods from 5 d to I month. These agreed, within error, with mean concentrations determined from grab samples but rigorous field validation of long-term (month) deployments of DGT devices proved impossible using conventional sampling procedures, due to loss Of Cs-137 to container walls. Identified limitations of the DGT technique included probable AMP degradation over longer periods and calibration problems if large changes in temperature and concentration occurred together. Potential limitations due to biofilm growth were considered not to be significant. Despite the limitations, the technique appears to measure concentrations accurately for deployment times of 1 month or less. It has several advantages over traditional sampling methods for monitoring radionuclides in the solution/dissolved phase, including its simplicity, provision of time-averaged mean concentrations, and automatic in-situ concentration onto a medium with ideal counting geometry for gamma spectrometry.
引用
收藏
页码:4530 / 4535
页数:6
相关论文
共 12 条
[1]  
CARRICK TR, 1982, CONCENTRATION MAJOR
[2]   Performance characteristics for the measurement of Cs and Sr by diffusive gradients in thin films (DGT) [J].
Chang, LY ;
Davison, W ;
Zhang, H ;
Kelly, M .
ANALYTICA CHIMICA ACTA, 1998, 368 (03) :243-253
[3]  
DAVISON W, 2000, IN SITU MONITORING A, P496
[4]  
KELLY M, UNPUB
[5]   Cesium absorption from acidic solutions using ammonium molybdophosphate on a polyacrylonitrile support (AMP-PAN) [J].
Miller, CJ ;
Olson, AL ;
Johnson, CK .
SEPARATION SCIENCE AND TECHNOLOGY, 1997, 32 (1-4) :37-50
[6]  
*MIN AGR FISH FOOD, 1999, RAD FOOD ENV 1998
[7]  
MOLERO J, 1993, RADIOCHIM ACTA, V62, P159
[8]   Two-dimensional and fine structure in the concentrations of iron and manganese in sediment pore-waters [J].
Shuttleworth, SM ;
Davison, W ;
Hamilton-Taylor, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (23) :4169-4175
[9]  
SMITH E, IN PRESS WATER RES
[10]  
Thorne M.C., 1983, RADIONUCLIDE DISTRIB, V1