Determination of dopamine in rat striatum by microdialysis and high-performance liquid chromatography with electrochemical detection on a functionalized multi-wall carbon nanotube electrode

被引:50
作者
Lin, L [1 ]
Qiu, PH
Yang, LZ
Cao, XN
Jin, LT
机构
[1] Wenzhou Med Coll, Dept Pharm, Wenzhou 325035, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
基金
中国国家自然科学基金;
关键词
multi-wall carbon nanotubes; chemically modified electrode; high-performance liquid chromatography; dopamine; microdialysis;
D O I
10.1007/s00216-005-0275-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High performance liquid chromatography coupled with microdialysis sampling and electrochemical detection (HPLC-ECD) has been used to determine dopamine (DA). In the HPLC-ECD a multi-wall carbon nanotube electrode chemically modified with carboxyl groups (MWNT-COOH CME) was used as the working electrode for determination of DA. The results indicated that the MWNT-COOH CME enabled efficient electrocatalytic oxidation of DA with relatively high sensitivity and stability and long life. Peak currents for dopamine were linearly dependent on concentration in the range 5.0x10(-9) to 5.0x10(-5) mol L-1 and the calculated detection limit (S/N=3) was 2.5x10(-9) mol L-1. The method had been successfully used to measure dopamine in rat striatal microdialysate. To study the physiological effect of nitric oxide (NO) on striatal release of DA, 0.5 mmol L-1 sodium nitroprusside (SNP) was a continuously perfused into rat striatum. This resulted in a 46% increase in DA basal level.
引用
收藏
页码:1308 / 1313
页数:6
相关论文
共 27 条
  • [1] Mechanisms underlying domoic acid-induced dopamine release from striatum:: An in vivo microdialysis study
    Alfonso, M
    Durán, R
    Campos, F
    Perez-Vences, D
    Faro, LRF
    Arias, B
    [J]. NEUROCHEMICAL RESEARCH, 2003, 28 (10) : 1487 - 1493
  • [2] Bao XM., 1991, STEREOTAXIC ATLAS RA
  • [3] Carbon nanotube electrode for oxidation of dopamine
    Britto, PJ
    Santhanam, KSV
    Ajayan, PM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01): : 121 - 125
  • [4] Britto PJ, 1999, ADV MATER, V11, P154, DOI 10.1002/(SICI)1521-4095(199902)11:2<154::AID-ADMA154>3.0.CO
  • [5] 2-B
  • [6] Simultaneous determination of aromatic amines by liquid chromatography coupled with carbon nanotubes/poly (3-methylthiophene) modified dual-electrode
    Cao, XN
    Li, JH
    Xu, HH
    Zhan, JR
    Lin, L
    Yamamoto, K
    Jin, LT
    [J]. CHROMATOGRAPHIA, 2004, 59 (3-4) : 167 - 172
  • [7] Amperometric determination of 6-mercaptopurine on functionalized multi-wall carbon nanotubes modified electrode by liquid chromatography coupled with microdialysis and its application to pharmacokinetics in rabbit
    Cao, XN
    Lin, L
    Zhou, YY
    Shi, GY
    Zhang, W
    Yamamoto, K
    Jin, LT
    [J]. TALANTA, 2003, 60 (05) : 1063 - 1070
  • [8] Protein electrochemistry at carbon nanotube electrodes
    Davis, JJ
    Coles, RJ
    Hill, HAO
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2): : 279 - 282
  • [9] Hou Jing-Guo, 2002, Se Pu, V20, P140
  • [10] HELICAL MICROTUBULES OF GRAPHITIC CARBON
    IIJIMA, S