New thrombolytic brush catheter in thrombosed polytetrafluoroethylene dialysis grafts: Preclinical animal study

被引:8
作者
Castaneda, F
Wyffels, PL
Pater, JC
Swischuk, JL
Li, RZ
Cole, BA
Cragg, AH
机构
[1] Univ Illinois, Coll Med, Dept Radiol, Peoria, IL 61605 USA
[2] Univ Illinois, Coll Med, Dept Surg, Peoria, IL 61605 USA
[3] Univ Illinois, Coll Med, Dept Pathol, Peoria, IL 61605 USA
[4] Fairview Univ Med Ctr, Dept Radiol, Minneapolis, MN USA
关键词
catheters and catheterization; technology; dialysis; grafts; thrombosis; thrombolysis;
D O I
10.1016/S1051-0443(98)70394-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the safety, efficacy, endothelial changes, and risks of pulmonary embolic events after the use of a mew thrombolytic brush catheter in mature thrombosed polytetrafluoroethylene (PTFE) dialysis grafts in an animal model. MATERIALS AND METHODS: Loop configuration PTFE grafts were implanted in the femoral vessels of 12 canines 4 weeks before mechanical thrombosis was performed. The thrombus was allowed to consolidate for 24 hours in 10 animals, 72 hours in one animal, and 7 days in one animal, Standard percutaneous criss-cross catheter access was performed, and a soft, low-speed, brush (6 mm in diameter), aided by 250,000 U of periprocedural urokinase, was utilized for thrombolysis. The native vessels, just distal to the anastomosis, and lungs were evaluated macro- and microscopically, RESULTS: Thrombolysis was complete in all grafts with the exception of a small segment between the crossing of the access vascular sheaths. The total thrombolysis time ranged from 8 to 12 minutes; this included 5 minutes of pulse-spray lacing, No difference in thrombolysis time was found with regard to the age or amount of thrombus, Minimal endothelial changes were noted and no evidence of acute pulmonary embolus was found on necropsy or histologic studies, CONCLUSION: This method offers a simple, safe, and efficient means of recanalization of thrombosed PTFE dialysis grafts in this canine model.
引用
收藏
页码:793 / 798
页数:6
相关论文
共 28 条
[1]   MECHANICAL VERSUS PHARMACOMECHANICAL THROMBOLYSIS FOR THE TREATMENT OF THROMBOSED DIALYSIS ACCESS GRAFTS [J].
BEATHARD, GA .
KIDNEY INTERNATIONAL, 1994, 45 (05) :1401-1406
[2]   Mechanical thrombolysis for the treatment of thrombosed hemodialysis access grafts [J].
Beathard, GA ;
Welch, BR ;
Maidment, HJ .
RADIOLOGY, 1996, 200 (03) :711-716
[3]   RECURRENT THROMBOSIS OF POLYTETRAFLUOROETHYLENE DIALYSIS FISTULAS AFTER RECENT SURGICAL THROMBECTOMY - SALVAGE BY MEANS OF THROMBOLYSIS AND A ANGIOPLASTY [J].
BERGER, MF ;
ARUNY, JE ;
SKIBO, LK .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 5 (05) :725-730
[4]   MECHANICAL CLOT DISSOLUTION - NEW CONCEPT [J].
BILDSOE, MC ;
MORADIAN, GP ;
HUNTER, DW ;
CASTANEDAZUNIGA, WR ;
AMPLATZ, K .
RADIOLOGY, 1989, 171 (01) :231-233
[5]  
BRAUN WE, 1981, TRANSPLANT P, V13, P128
[6]  
Brunner M C, 1991, J Vasc Interv Radiol, V2, P503, DOI 10.1016/S1051-0443(91)72232-X
[7]   IMPROVED TREATMENT OF THROMBOSED HEMODIALYSIS ACCESS SITES WITH THROMBOLYSIS AND ANGIOPLASTY [J].
COHEN, MAH ;
KUMPE, DA ;
DURHAM, JD ;
ZWERDLINGER, SC .
KIDNEY INTERNATIONAL, 1994, 46 (05) :1375-1380
[8]   THROMBOSED DIALYSIS GRAFTS - EFFICACY OF INTRATHROMBIC DEPOSITION OF CONCENTRATED UROKINASE, CLOT MACERATION, AND ANGIOPLASTY [J].
DAVIS, GB ;
DOWD, CF ;
BOOKSTEIN, JJ ;
MARONEY, TP ;
LANG, EV ;
HALASZ, N .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (01) :177-181
[9]   WILL IATROGENIC PULMONARY EMBOLIZATION BE OUR PULMONARY EMBARRASSMENT [J].
DOLMATCH, BL ;
GRAY, RJ ;
HORTON, KM .
RADIOLOGY, 1994, 191 (03) :615-617
[10]  
EGGERS PW, 1992, 03329 BUR DAT MAN ST