Guidance for robustness/ruggedness tests in method validation

被引:424
作者
Vander Heyden, Y
Nijhuis, A
Smeyers-Verbeke, J
Vandeginste, BGM
Massart, DL
机构
[1] Free Univ Brussels, ChemoAC, Inst Pharmaceut, B-1090 Brussels, Belgium
[2] Unilever Res Labs Vlaardingen, NL-3130 AC Vlaardingen, Netherlands
关键词
robustness test; ruggedness test; method validation; method development; system suitability limits;
D O I
10.1016/S0731-7085(00)00529-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper. is intended to give guidance in setting-up and interpreting a robustness test. The different steps in a robustness test are discussed and illustrated with examples. The recommendations given for the different steps are based on approaches found in the literature, several case studies performed by the authors and discussions of the authors within a commission of the French SFSTP (Societe Francaise des Sciences et Techniques Pharmaceutiques). In the end of the paper a worked-out example is given of a robustness test case study set up and interpreted according to the guidelines. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:723 / 753
页数:31
相关论文
共 41 条
[1]  
[Anonymous], 1996, VALIDATION ANAL PROC, P1
[2]  
[Anonymous], CHEMOMETRICS EXPT DE
[3]  
[Anonymous], 1994, TEXT VALIDATION ANAL
[4]  
[Anonymous], STP PHARM PRATIQUES
[5]  
Box G.E.P., 1978, STATISTICS EXPT, P306
[6]   APPLICATION ISSUES IN BIOANALYTICAL METHOD VALIDATION, SAMPLE ANALYSIS AND DATA REPORTING [J].
DADGAR, D ;
BURNETT, PE ;
CHOC, MG ;
GALLICANO, K ;
HOOPER, JW .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (02) :89-97
[7]  
Daniel C., 1959, TECHNOMETRICS, V1, P311, DOI [10.1080/00401706.1959.10489866, DOI 10.1080/00401706.1959.10489866]
[8]  
DONG F, 1993, STAT SINICA, V3, P209
[9]  
DOORNBOS DA, 1990, DATA HANDL SCI TECHN, V6, P85, DOI 10.1016/S0922-3487(08)70158-8
[10]  
*EUR, 1995, FOC AN CHEM EUR QUAN