Adhesion and activation of platelets and polymorphonuclear granulocyte cells at TiO2 surfaces

被引:77
作者
Nygren, H [1 ]
Eriksson, C [1 ]
Lausmaa, J [1 ]
机构
[1] CHALMERS UNIV TECHNOL, DEPT APPL PHYS, S-41296 GOTHENBURG, SWEDEN
来源
JOURNAL OF LABORATORY AND CLINICAL MEDICINE | 1997年 / 129卷 / 01期
关键词
D O I
10.1016/S0022-2143(97)90159-1
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The initial reactions of two TiO2 surfaces with blood were investigated by short-time exposure to capillary blood and analysis of surface-adsorbed plasma proteins and surface-adhering cells by using immunofluorescence techniques. Antibodies directed against platelet membrane antigen and P-selectin were used to visualize platelet adhesion and activation. Acridine orange and anti-CD11b were used to detect adhesion and activation of polymorphonuclear granulocytes (PMNs). Antibodies against thrombospondin were used as markers for platelet alpha-granules. The fluorescence intensity was quantitated by computer-aided image analysis. Commercially pure, polished sheet titanium was oxidized in two different ways: (1) the natural oxide was dissolved with hydrofluoric acid and a new oxide layer was grown by oxidation in nitric acid, or (2) annealing was performed at 700 degrees C in air. Auger electron spectroscopy and x-ray photoelectron spectroscopy showed that both surfaces had similar composition consisting of TiO2 covered by a carbonaceous surface contamination layer. The thickness of the oxide layer was 4 nm on the acid-oxidized surface and 39 nm on the annealed surface. Optical profilometry and scanning electron microscopy showed that the acid-oxidized surface was rough and the annealed surface was smooth. The fibrinogen/prothrombin-thrombin ratio in the initial protein film differed between the surfaces. The number of adhering platelets was larger at the surface with a high surface concentration of adsorbed fibrinogen. Platelet activation (CD62) and priming of PMNs (CD 11b) were also significantly higher on the acid-oxidized surface. The results indicate that non-self recognition of biomaterials is an array of transient reactions comprising protein-material, protein-cell, and cell-cell interactions.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 45 条
[1]  
ALAEDDINE S, 1995, BIOINTERFACES, V5, P227
[2]   AUGER AND X-RAY PHOTOELECTRON SPECTROSCOPIC AND ELECTROCHEMICAL CHARACTERIZATION OF TITANIUM THIN-FILM ELECTRODES [J].
ARMSTRONG, NR ;
QUINN, RK .
SURFACE SCIENCE, 1977, 67 (02) :451-468
[3]  
ARNAOUT MA, 1990, BLOOD, V75, P1037
[4]   MICROSTRUCTURE AND MORPHOLOGY OF SURFACE OXIDE-FILMS ON TI-6AL-4V [J].
ASK, M ;
ROLANDER, U ;
LAUSMAA, J ;
KASEMO, B .
JOURNAL OF MATERIALS RESEARCH, 1990, 5 (08) :1662-1667
[5]   STRUCTURE AND GROWTH OF ANODIC OXIDE-FILMS ON TITANIUM AND TA6V ALLOY [J].
BLONDEAU, G ;
FROELICHER, M ;
FROMENT, M ;
HUGOTLEGOFF, A .
JOURNAL OF THE LESS-COMMON METALS, 1977, 56 (02) :215-222
[6]  
Bothe T, 1940, SURG GYNECOL OBSTET, V71, P598
[7]  
BRUNETTE DM, 1988, SURFACE CHARACTERIZA, P203
[8]  
CHINN JA, 1991, THROMB HAEMOSTASIS, V65, P608
[9]  
CORRAL L, 1990, BIOCHEM BIOPH RES CO, V173, P1349
[10]   HEMODIALYSIS LEUKOPENIA - PULMONARY VASCULAR LEUKOSTASIS RESULTING FROM COMPLEMENT ACTIVATION BY DIALYZER CELLOPHANE MEMBRANES [J].
CRADDOCK, PR ;
FEHR, J ;
DALMASSO, AP ;
BRIGHAM, KL ;
JACOB, HS .
JOURNAL OF CLINICAL INVESTIGATION, 1977, 59 (05) :879-888