Automated mass spectrometry imaging with a matrix-assisted laser desorption ionization time-of-flight instrument

被引:146
作者
Stoeckli, M [1 ]
Farmer, TB [1 ]
Caprioli, RM [1 ]
机构
[1] Vanderbilt Univ, Sch Med, Mass Spectrometry Res Ctr, Nashville, TN 37232 USA
关键词
D O I
10.1016/S1044-0305(98)00126-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The automated use of a matrix-assisted laser desorption ionization (MALDI) mass spectrometer (MS) is described for image analysis of samples through implementation of new software for instrument control, data acquisition, and data analysis. The software permits automated acquisition of MS MALDI spectra to form an ordered data array and contains display features to provide images at one or more mass-to-charge ratio values. The technique can be used to scan tissue samples, blotted samples, gels, or other sample surfaces where the image analysis of that sample is required. The program achieves a time of typically 1 s per image point, permitting an analysis made up of large numbers of points with high spatial resolution up to 850 dpi. The features of the software are demonstrated in this paper with samples of printed images, where visible images can be compared to those obtained by mass spectrometry. Quantitative aspects are introduced by analyzing a series of sample spots containing different amounts of several proteins. (J Am. Soc Mass Spectrom 1999, 10, 67-71) (C) 1999 American Society for Mass Spectrometry.
引用
收藏
页码:67 / 71
页数:5
相关论文
共 16 条
[1]  
BRIGGS D, 1992, PRACTICAL SURFACE AN, V2, P367
[2]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[3]   Atomic and molecular imaging at the single-cell level with TOF-SIMS [J].
Colliver, TL ;
Brummel, CL ;
Pacholski, ML ;
Swanek, FD ;
Ewing, AG ;
Winograd, N .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2225-2231
[4]  
HAIYING Z, 1998, THESIS U TEXAS HLTH
[5]  
HUBER M, 1994, P 42 ASMS C MASS SPE, P1044
[6]  
Iancu TC, 1996, BIOMETALS, V9, P57
[7]  
McMahon JM, 1996, RAPID COMMUN MASS SP, V10, P335, DOI 10.1002/(SICI)1097-0231(199602)10:3<335::AID-RCM516>3.3.CO
[8]  
2-N
[9]   Imaging of subcellular structures by scanning ion microscopy and mass spectrometry. Advantage of cryofixation and freeze substitution procedure over chemical preparation [J].
Mony, MC ;
Larras-Regard, E .
BIOLOGY OF THE CELL, 1997, 89 (03) :199-210
[10]  
Pestaner JP, 1996, J FORENSIC SCI, V41, P1060