Portable computerized polysomnography in attended and unattended settings

被引:43
作者
Mykytyn, IJ [1 ]
Sajkov, D [1 ]
Neill, AM [1 ]
McEvoy, RD [1 ]
机构
[1] Repatriat Gen Hosp, Sleep Disorders Unit, Daw Pk, SA 5041, Australia
关键词
home monitoring; portable polysomnography; sleep apnea;
D O I
10.1378/chest.115.1.114
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We compared the validity of a new portable polysomnographic recorder against a laboratory-based polysomnographic system from the same manufacturer. Design and patients: Simultaneous, full polysomnographic recordings from the portable device (PSGP) and the laboratory-based system (PSGL) were obtained using separate sets of sensors on 20 patients referred for investigation of sleep apnea, Setting: After initial optimization of signals, the portable device was left unattended in 10 of the patients (to simulate home studies), while in the other 10 the signals were reviewed on a laptop computer screen and adjustments to electrode or sensor placement made as needed during the studies. Recordings were manually scored by a technologist blinded to the origin of the data, Measurements and results: The quality of signals was comparable between the PSGP and PSGL studies, apart from a slight decrease in respiratory signal quality dating PSGP studies that led to reduced confidence in respiratory event scoring. SaO(2) signal loss was also greater in unattended PSGP, There was good agreement between PSGP and PSGL for sleep variables and the apnea-hypopnea index (r = 0.99). The periodic limb movement index was slightly lower during unattended PSGP, Blinded physician assessment of the records led to a recommendation for repeat studies due to poor signal quality in one (10%) attended and one (10%) unattended per-table recording. There was no significant discordance between PSGP and PSGL in the final diagnostic formulations, Conclusion: Portable polysomnography is a viable alternative to laboratory-based polysomnograph! and may be improved further by better sensor attachment.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
BONNET M, 1993, SLEEP, V16, P749
[3]  
BONNET MH, 1992, SLEEP, V15, P526
[4]   AN EVALUATION OF AMBULATORY, CASSETTE EEG MONITORING .2. DETECTION OF INTERICTAL ABNORMALITIES [J].
EBERSOLE, JS ;
LEROY, RF .
NEUROLOGY, 1983, 33 (01) :8-18
[5]   PORTABLE RECORDING IN THE ASSESSMENT OF OBSTRUCTIVE SLEEP-APNEA [J].
FERBER, R ;
MILLMAN, R ;
COPPOLA, M ;
FLEETHAM, J ;
MURRAY, CF ;
IBER, C ;
MCCALL, V ;
NINOMURCIA, G ;
PRESSMAN, M ;
SANDERS, M ;
STROHL, K ;
VOTTERI, B ;
WILLIAMS, A .
SLEEP, 1994, 17 (04) :378-392
[6]   A CAUSE OF EXCESSIVE DAYTIME SLEEPINESS - THE UPPER AIRWAY-RESISTANCE SYNDROME [J].
GUILLEMINAULT, C ;
STOOHS, R ;
CLERK, A ;
CETEL, M ;
MAISTROS, P .
CHEST, 1993, 104 (03) :781-787
[7]   EVALUATION OF A MICROPROCESSOR-BASED PORTABLE HOME MONITORING-SYSTEM TO MEASURE BREATHING DURING SLEEP [J].
GYULAY, S ;
GOULD, D ;
SAWYER, B ;
POND, D ;
MANT, A ;
SAUNDERS, N .
SLEEP, 1987, 10 (02) :130-142
[8]  
HOELSCHER TJ, 1989, SLEEP, V12, P133
[9]   4-CHANNEL 24 HOUR CASSETTE RECORDER FOR LONG-TERM EEG MONITORING OF AMBULATORY PATIENTS [J].
IVES, JR ;
WOODS, JF .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 39 (01) :88-92
[10]   SLEEP-APNEA IN PATIENTS WITH QUADRIPLEGIA [J].
MCEVOY, RD ;
MYKYTYN, I ;
SAJKOV, D ;
FLAVELL, H ;
MARSHALL, R ;
ANTIC, R ;
THORNTON, AT .
THORAX, 1995, 50 (06) :613-619