Flow-through reactors are commonly used to control and optimize reagent delivery and product removal. Although recent research suggests that transcription reactions using picogram quantities of cDNA produce RNA efficiently in a flow-through microreactor, there has not been a detailed study on the mass transport and reagent dependence of microfluidic transcription reactions. We present a novel microreactor that contains H5 influenza cDNA immobilized directly onto the reactor walls to study the kinetics and reagent dependence of in vitro transcription reactions on a microfluidic platform. Enzyme and the rNTP substrate continuously flow over the cDNA and create RNA, which flows to a downstream collection well. Using nanogram quantities of cDNA, we found that enzyme limiting conditions caused by the concentration of cDNA in a small-volume microreactor channel may be partially overcome as the enzyme binds and concentrates near the channel wall. Kinetics confirm this phenomenon and show that the timescale for enzyme binding can be approximated by t(f) = cDNA/Q[E]. Surprisingly, on-chip transcription reactions have a strong dependence on the rNTP concentration from 5 to 9 mM despite a low consumption rate of rNTP molecules that is largely independent of the flow rate. Faster flow rates decrease the time it takes to fill DNA promoter sites with enzyme while additionally refreshing rNTP and MgCl2 to allow for a greater consumption of rNTP. These two effects cause reactions with higher concentrations of cDNA in the reactor channel to have a greater dependence on the flow rate. At high flow rates (> 0.37 nL/s), the reaction rate begins to drop, likely because of the release and escape of enzyme molecules from the cDNA layer. This critical flow rate can be predicted by a new modified Peclet number, Pe(m) = LcV/D, where Le is the full length of the tightly packed cDNA molecules, V is the velocity at the DNA/fluid interface, and D is the diffusivity of the enzyme molecule. Together, these insights can inspire reactor designs for a variety of applications.
引用
收藏
页码:14372 / 14379
页数:8
相关论文
共 37 条
[1]   Diffusion of nucleoside triphosphates and role of the entry site to the RNA polymerase II active center [J].
Batada, NN ;
Westover, KD ;
Bushnell, DA ;
Levitt, M ;
Kornberg, RD .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (50) :17361-17364
[2]   DIFFUSION OF ADENOSINE TRIPHOSPHATE THROUGH AQUEOUS SOLUTIONS [J].
BOWEN, WJ ;
MARTIN, HL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1964, 107 (01) :30-&
[3]   Modeling of repeated-batch transcription for production of RNA [J].
Davis, RH ;
Breckenridge, NC .
JOURNAL OF BIOTECHNOLOGY, 1999, 71 (1-3) :25-37
[4]   CONFORMATIONS OF POLYMERS ATTACHED TO AN INTERFACE [J].
DEGENNES, PG .
MACROMOLECULES, 1980, 13 (05) :1069-1075
[5]   Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics [J].
Dimov, Ivan K. ;
Garcia-Cordero, Jose L. ;
O'Grady, Justin ;
Poulsen, Claus R. ;
Viguier, Caroline ;
Kent, Lorcan ;
Daly, Paul ;
Lincoln, Bryan ;
Maher, Majella ;
O'Kennedy, Richard ;
Smith, Terry J. ;
Ricco, Antonio J. ;
Lee, Luke P. .
LAB ON A CHIP, 2008, 8 (12) :2071-2078
[6]   Quantitation of human immunodeficiency virus type 1 RNA in cell free seminal plasma: Comparison of NASBA(TM) with Amplicor(TM) reverse transcription-PCR amplification and correlation with quantitative culture [J].
Dyer, JR ;
Gilliam, BL ;
Eron, JJ ;
Grosso, L ;
Cohen, MS ;
Fiscus, SA .
JOURNAL OF VIROLOGICAL METHODS, 1996, 60 (02) :161-170
[7]   RNA amplification chip with parallel microchannels and droplet positioning using capillary valves [J].
Furuberg, Liv ;
Mielnik, Michal ;
Gulliksen, Anja ;
Solli, Lars ;
Johansen, Ib-Rune ;
Voitel, Jorg ;
Baier, Tobias ;
Riegger, Lutz ;
Karlsen, Frank .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2008, 14 (4-5) :673-681
[8]   Real-time monitoring of aRNA production during T7 amplification to prevent the loss of sample representation during microarray hybridization sample preparation [J].
Gilbert, Isabelle ;
Scantland, Sara ;
Dufort, Isabelle ;
Gordynska, Olga ;
Labbe, Aurelie ;
Sirard, Marc-Andre ;
Robert, Claude .
NUCLEIC ACIDS RESEARCH, 2009, 37 (08)
[9]   ISOTHERMAL, INVITRO AMPLIFICATION OF NUCLEIC-ACIDS BY A MULTIENZYME REACTION MODELED AFTER RETROVIRAL REPLICATION [J].
GUATELLI, JC ;
WHITFIELD, KM ;
KWOH, DY ;
BARRINGER, KJ ;
RICHMAN, DD ;
GINGERAS, TR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (05) :1874-1878
[10]  
Gulliksen A, 2005, LAB CHIP, V5, P416, DOI 10.1039/b415525d