Use of DNA repair enzymes in electrochemical detection of damage to DNA bases in vitro and in cells

被引:54
作者
Cahová-Kucharíková, K [1 ]
Fojta, M [1 ]
Mozga, T [1 ]
Palecek, E [1 ]
机构
[1] Acad Sci Czech Republ, Inst Biophys, Brno 61265, Czech Republic
关键词
D O I
10.1021/ac048423x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical measurements at mercury or solid amalgam electrodes offer a highly sensitive detection of DNA strand breaks. On the other hand, electrochemical detection of damage to DNA bases at any electrode is usually much less sensitive. In this paper, we propose a new voltammetric method for the detection of the DNA base damage based on enzymatic conversion of the damaged DNA bases to single-strand breaks (ssb), single-stranded (ss) DNA regions, or both. Supercoiled DNA exposed to UV light was specifically cleaved by T4 endonuclease V, an enzyme recognizing pyrimidine dimers, the major products of photochemical DNA damage. Apurinic sites (formed in dimethyl sulfate-modified DNA) were determined after treating the DNA with E. coli exonuclease III, an enzyme introducing ssb at the abasic sites and degrading one of the DNA strands. The ssb or ssDNA regions, or both, were detected by adsorptive transfer stripping alternating current voltammetry at the mercury electrode. This technique offers much better sensitivity and selectivity of DNA base damage detection than any other electrochemical method. It is not limited to DNA damage in vitro, but it can detect also DNA base damage induced in living bacterial cells.
引用
收藏
页码:2920 / 2927
页数:8
相关论文
共 70 条
  • [1] [Anonymous], ENCY ELECTROCHEMISTR
  • [2] BLACKBURN MG, 1990, NUCL ACIDS CHEM BIOL
  • [3] A simple and sensitive method for in vitro quantitation of abasic sites in DNA
    Boturyn, D
    Constant, JF
    Defrancq, E
    Lhomme, J
    Barbin, A
    Wild, CP
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 1999, 12 (06) : 476 - 482
  • [4] DETERMINATION OF SUBMICROGRAM QUANTITIES OF CIRCULAR DUPLEX DNA IN PLASMID SAMPLES BY ADSORPTIVE STRIPPING VOLTAMMETRY
    BOUBLIKOVA, P
    VOJTISKOVA, M
    PALECEK, E
    [J]. ANALYTICAL LETTERS, 1987, 20 (02) : 275 - 291
  • [5] Brett AMO, 2000, ELECTROANAL, V12, P969, DOI 10.1002/1521-4109(200008)12:12<969::AID-ELAN969>3.0.CO
  • [6] 2-O
  • [7] ANALYSIS OF UV-INDUCED DNA PHOTOPRODUCTS BY P-32 POSTLABELING
    BYKOV, VJ
    KUMAR, R
    FORSTI, A
    HEMMINKI, K
    [J]. CARCINOGENESIS, 1995, 16 (01) : 113 - 118
  • [8] Facts and artifacts in the measurement of oxidative base damage to DNA
    Cadet, J
    D'Ham, C
    Douki, T
    Pouget, JP
    Ravanat, JL
    Sauvaigo, S
    [J]. FREE RADICAL RESEARCH, 1998, 29 (06) : 541 - 550
  • [9] Trace measurements of plasmid DNAs by adsorptive stripping potentiometry at carbon paste electrodes
    Cai, XH
    Rivas, G
    Farias, PAM
    Shiraishi, H
    Wang, J
    Fojta, M
    Palecek, E
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 40 (01): : 41 - 47
  • [10] PROPERTIES OF A MONOCLONAL-ANTIBODY FOR THE DETECTION OF ABASIC SITES, A COMMON DNA LESION
    CHEN, BX
    KUBO, K
    IDE, H
    ERLANGER, BF
    WALLACE, SS
    KOW, YW
    [J]. MUTATION RESEARCH, 1992, 273 (03): : 253 - 261