Evaluation of optimized compensators on a 3D planning system

被引:20
作者
Basran, PS [1 ]
Ansbacher, W [1 ]
Field, GC [1 ]
Murray, BR [1 ]
机构
[1] Cross Canc Inst, Dept Med Phys, Edmonton, AB T6G 1Z2, Canada
关键词
radiotherapy; optimization; compensators; treatment planning systems; photon dose calculation;
D O I
10.1118/1.598369
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A commercially available treatment planning system contains several functions that allow for the automation of missing tissue and optimized compensators, where the former retracts the bolus toward the source, and the latter attempts, by iteration, to establish a uniform dose at some user defined depth. The intent of this paper is to report on the compensators designed by the system and to compare them to those devised through conventional techniques. It is demonstrated that the system can model the dosimetric effects of compensators with a high degree of accuracy; measured and predicted doses agree to within 3%. Optimized compensators show slightly improved dose uniformity over thickness reduced compensators. Both show significantly improved uniformity over compensators that simply retract the bolus geometry. In cases where internal inhomogeneities exist, however, the dose uniformity from the optimized compensators vary by as much as 6% at the target depth. These deviations are comparable to the errors of the inhomogeneity algorithm itself. The pathlength reduction technique has been applied to both missing tissue and inhomogeneity compensation, and it has been found that for inhomogeneity compensation, the pathlength reduced compensators produce more uniform distributions than those generated by the optimization algorithm. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00510-0].
引用
收藏
页码:1837 / 1844
页数:8
相关论文
共 18 条
[1]   MODELING TRANSMISSION AND SCATTER FOR PHOTON-BEAM ATTENUATORS [J].
AHNESJO, A ;
WEBER, L ;
NILSSON, P .
MEDICAL PHYSICS, 1995, 22 (11) :1711-1720
[2]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[3]   MISSING TISSUE COMPENSATORS - EVALUATION AND OPTIMIZATION OF A COMMERCIAL SYSTEM [J].
ANSBACHER, W ;
ROBINSON, DM ;
SCRIMGER, JW .
MEDICAL PHYSICS, 1992, 19 (05) :1267-1272
[4]  
BASRAN PS, 1997, THESIS U ALBERTA
[5]  
Beddar A S, 1994, Med Dosim, V19, P227
[6]   COMPENSATING FILTERS FOR HIGH-ENERGY X-RAYS [J].
BOYER, AL .
MEDICAL PHYSICS, 1982, 9 (03) :429-433
[7]   A COMPENSATOR FOR VARIATIONS IN TISSUE THICKNESS FOR HIGH ENERGY BEAMS [J].
ELLIS, F ;
HALL, EJ ;
OLIVER, R .
BRITISH JOURNAL OF RADIOLOGY, 1959, 32 (378) :421-422
[8]   COMPENSATION FOR TISSUE INHOMOGENEITY IN COBALT-60 THERAPY [J].
ELLIS, F ;
FELDMAN, A ;
OLIVER, R .
BRITISH JOURNAL OF RADIOLOGY, 1964, 37 (442) :795-798
[9]   COMPUTER-AIDED DESIGN AND VERIFICATION OF MEGAVOLTAGE TISSUE COMPENSATORS FOR OBLIQUE BEAMS [J].
FADDEGON, BA ;
PFALZNER, P .
MEDICAL PHYSICS, 1988, 15 (05) :757-762
[10]  
JUSINIC PA, 1994, MED PHYS, V21, P357