Discrimination of sinus rhythm, atrial flutter, and atrial fibrillation using bipolar endocardial signals

被引:8
作者
Jung, J [1 ]
Hohenberg, G [1 ]
Heisel, A [1 ]
Strauss, D [1 ]
Schieffer, H [1 ]
Fries, R [1 ]
机构
[1] Univ Homburg, Med Klin, D-6650 Homburg, Germany
关键词
arrhythmia detection; atrial fibrillation; atrial flutter;
D O I
10.1111/j.1540-8167.1998.tb00955.x
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Introduction: Analysis of endocardial signals obtained from an electrode located in the right atrium as realized in newly designed dual chamber, implantable cardioverter defibrillators might be used to provide additional therapeutic options, such as overdrive pacing or low-energy atrial cardioversion for the treatment of concomitant atrial flutter (AFL) or atrial fibrillation (AF). Therefore, we developed a computer algorithm for discrimination of normal sinus rhythm (NSR), AFL, and AF that may lead to adequate differential therapy of atrial tachyarrhythmias in an automated mode. Methods and Results: During an electrophysiologic study, bipolar endocardial signals from the high right atrium were obtained in 28 patients during sustained AFL or AF and after restoration of NSR. A total of 286 data segments of 5-second duration were recorded (NSR: 96, AFL: 86, AF: 104). Mean atrial cycle length (R;ICL), standard deviation of mean atrial cycle length (SDCL), and index of irregularity (IR), defined as the ratio between R;ICL and SDCL, were calculated for each data segment. A cutoff of 315 msec for R ICL allowed discrimination of NSR from atrial tachyarrhythmias with 100% sensitivity and specificity. For discrimination of AF from AFL by using SDCL, a cutoff value of 11.5 msec led to a sensitivity of 99% and a specificity of 90%. Best discrimination of AF from AFL was found for the criterion IR greater than or equal to 7.5%, resulting in a sensitivity of 100% with a specificity of 95 % for AF detection. Conclusion: The investigated algorithm provides discrimination of NSR, AFL, and AF with high sensitivity and specificity. Incorporation of this algorithm in an implantable automated antitachycardia device may lead to adequate differential therapy in patients suffering from spontaneous episodes of AF and AFL.
引用
收藏
页码:689 / 695
页数:7
相关论文
共 13 条
[1]
IMPLANTABLE CARDIOVERTER DEFIBRILLATOR FOR PREVENTION OF SUDDEN CARDIAC DEATH IN PATIENTS WITH VENTRICULAR-TACHYCARDIA AND VENTRICULAR-FIBRILLATION - ICD THERAPY IN SUDDEN CARDIAC DEATH [J].
AKHTAR, M ;
JAZAYERI, M ;
SRA, J ;
TCHOU, P ;
ROVANG, K ;
BLANCK, Z ;
DHALA, A ;
DESHPANDE, S ;
AXTELL, K .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03) :511-518
[2]
BOCKER D, 1993, J AM COLL CARDIOL, V21, P1638
[3]
ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS [J].
GRIMM, W ;
FLORES, BF ;
MARCHLINSKI, FE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1667-1673
[4]
Atrial defibrillation: Can modifications in current implantable cardioverter-defibrillators achieve this? [J].
Heisel, A ;
Jung, J ;
Fries, R ;
Schieffer, H ;
Ozbek, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (5A) :119-126
[5]
DIAGNOSIS OF ATRIAL-FIBRILLATION USING ELECTROGRAMS FROM CHRONIC LEADS - EVALUATION OF COMPUTER ALGORITHMS [J].
JENKINS, J ;
NOH, KH ;
GUEZENNEC, A ;
BUMP, T ;
ARZBAECHER, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (05) :622-631
[6]
Initial clinical experience with an implantable human atrial defibrillator [J].
Lau, CP ;
Tse, HF ;
Lok, NS ;
Lee, KLF ;
Ho, DSW ;
Sopher, M ;
Murgatroyd, F ;
Camm, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :220-225
[7]
Preliminary clinical experience with the first dual chamber pacemaker defibrillator [J].
Lavergne, T ;
Daubert, JC ;
Chauvin, M ;
Dolla, E ;
Kacet, S ;
Leenhardt, A ;
Mabo, P ;
Ritter, P ;
Sadoul, N ;
Saoudi, N ;
Henry, C ;
Nitzsche, R ;
Ripart, A ;
Murgatroyd, F .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :182-188
[8]
TERMINATION OF MALIGNANT VENTRICULAR ARRHYTHMIAS WITH AN IMPLANTED AUTOMATIC DEFIBRILLATOR IN HUMAN-BEINGS [J].
MIROWSKI, M ;
REID, PR ;
MOWER, MM ;
WATKINS, L ;
GOTT, VL ;
SCHAUBLE, JF ;
LANGER, A ;
HEILMAN, MS ;
KOLENIK, SA ;
FISCHELL, RE ;
WEISFELDT, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1980, 303 (06) :322-324
[9]
PROGRAMMABLE VT DETECTION ENHANCEMENTS IN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY [J].
NEUZNER, J ;
PITSCHNER, HF ;
SCHLEPPER, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (03) :539-547
[10]
NEUZNER J, 1995, J AMBUL MONITOR, V88, P1