Magnitude and time course of hemodynamic responses to Mueller maneuvers in patients with congestive heart failure

被引:64
作者
Hall, MJ
Ando, SI
Floras, JS
Bradley, TD
机构
[1] Toronto Hosp, Dept Med, Toronto, ON M5G 2C4, Canada
[2] Mt Sinai Hosp, Dept Med, Toronto, ON M5G 1X5, Canada
[3] Univ Toronto, Cardiovasc Res Ctr, Toronto, ON M5G 2C4, Canada
关键词
breath holds; obstructive apnea; cardiopulmonary interactions;
D O I
10.1152/jappl.1998.85.4.1476
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To simulate the immediate hemodynamic effect of negative intrathoracic pressure during obstructive apneas in congestive heart failure (CHF), without inducing confounding factors such as hypoxia and arousals from sleep, eight awake patients performed, at random, 15-s Mueller maneuvers (MM) at target intrathoracic pressures of -20 (MM -20) and -40 cmH(2)O (MM -40), confirmed by esophageal pressure, and 15-s breath holds, as apneic time controls. Compared with quiet breathing, at baseline, before these interventions, the immediate effects [first 5 cardiac cycles (SD), P values refer to MM -40 compared with breath holds] of apnea, MM -20, and MM -40 were, for left ventricular (LV) systolic transmural pressure (Ptm), 1.0 +/- 1.9, 7.2 +/- 3.5, and 11.3 +/- 6.8 mmHg (P < 0.01); for systolic blood pressure (SBP), 2.9 +/- 2.6, -5.5 +/- 3.4, and -12.1 +/- 6.8 mmHg (P < 0.01); and for stroke volume (SV) index, 0.4 +/- 2.8, -4.1 +/- 2.8, and -6.9 +/- 2.3 ml/m(2) (P < 0.001), respectively. Corresponding values over the last five cardiac cycles were for LVPtm 6.4 +/- 4.4, 5.4 +/- 6.6, and -4.5 +/- 9.1 mmHg (P < 0.01); for SEP 6.9 +/- 4.2, -8.2 +/- 7.7, and -24.2 +/- 6.9 mmHg (P < 0.01); and for SV index -0.4 +/- 2.1, -5.2 +/- 2.8, and -9.2 +/- 4.8 ml/m(2) (P < 0.001), respectively. Thus, in CHF patients, the initial hemodynamic response to the generation of negative intrathoracic pressure includes an immediate increase in LV afterload and an abrupt fall in SV. The magnitude of response is proportional to the intensity of the MM stimulus. By the end of a 15-s MM -40, LVPtm falls below baseline values, yet SV and SEP do not recover. Thus, when -40 cmH(2)O intrathoracic pressure is sustained, additional mechanisms, such as a drop in LV preload due to ventricular interaction, are engaged, further reducing SV. The net effect of MM -40 was a 33% reduction in SV index (from 27 to 18 ml/min(2)), and a 21% reduction in SEP (from 121 to 96 mmHg). Obstructive apneas can have adverse effects on systemic and, possibly, coronary perfusion in CHF through dynamic mechanisms that are both stimulus and time dependent.
引用
收藏
页码:1476 / 1484
页数:9
相关论文
共 36 条
[1]   Diastolic ventricular interaction in chronic heart failure [J].
Atherton, JJ ;
Moore, TD ;
Lele, SS ;
Thomson, HL ;
Galbraith, AJ ;
Belenkie, I ;
Tyberg, JV ;
Frenneaux, MP .
LANCET, 1997, 349 (9067) :1720-1724
[2]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[3]  
Bradley T D, 1996, J Card Fail, V2, P223, DOI 10.1016/S1071-9164(96)80045-5
[4]   EFFECT OF INTRA-THORACIC PRESSURE ON LEFT-VENTRICULAR PERFORMANCE [J].
BUDA, AJ ;
PINSKY, MR ;
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (09) :453-459
[5]   PULMONARY-EDEMA DUE TO OBSTRUCTIVE SLEEP-APNEA [J].
CHAUDHARY, BA ;
NADIMI, M ;
CHAUDHARY, TK ;
SPEIR, WA .
SOUTHERN MEDICAL JOURNAL, 1984, 77 (04) :499-502
[6]   Comparative hemodynamic effects of periodic obstructive and simulated central apneas in sedated pigs [J].
Chen, L ;
Scharf, SM .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (02) :485-494
[7]   SLEEP-APNEA AND NOCTURNAL ANGINA [J].
FRANKLIN, KA ;
NILSSON, JB ;
SAHLIN, C ;
NASLUND, U .
LANCET, 1995, 345 (8957) :1085-1087
[8]   RESPIRATORY MODULATION OF LEFT-VENTRICULAR STROKE VOLUME IN MAN MEASURED USING PULSED DOPPLER ULTRASOUND [J].
GUZ, A ;
INNES, JA ;
MURPHY, K .
JOURNAL OF PHYSIOLOGY-LONDON, 1987, 393 :499-512
[9]   THE EFFECT OF CORONARY INFLOW PRESSURE ON CORONARY VASCULAR-RESISTANCE IN THE ISOLATED DOG HEART [J].
HANLEY, FL ;
MESSINA, LM ;
GRATTAN, MT ;
HOFFMAN, JIE .
CIRCULATION RESEARCH, 1984, 54 (06) :760-772
[10]   Increased mortality associated with Cheyne-Stokes respiration in patients with congestive heart failure [J].
Hanly, PJ ;
ZuberiKhokhar, NS .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (01) :272-276