Feasibility study of x-ray diffraction computed tomography for medical imaging

被引:80
作者
Kleuker, U
Suortti, P
Weyrich, W
Spanne, P
机构
[1] European Synchrotron Radiat Facil, Med Imaging Grp, F-38043 Grenoble, France
[2] Univ Konstanz, Fac Chem, D-78457 Constance, Germany
关键词
D O I
10.1088/0031-9155/43/10/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A feasibility study of soft-tissue imaging based on x-ray wide-angle diffraction contrast has been performed at the medical beamline of the European Synchrotron Radiation Facility (ESRF). The technique employs computed-tomography algorithms to reconstruct from one data set the spatial distribution of several tissues differentiated by their diffraction properties. Radial diffraction profiles are measured in parallel projections from the sample and decomposed into material-selective weighting factors, which form the sinograms for the reconstructions. Attenuation effects-inherent in imaging techniques using scattered radiation-are efficiently corrected for by a ray-tracing method applied to the corresponding absorption image. Images of 7 cm diameter samples composed of fat, bone and muscle were generated at 60 and 80 keV x-ray energy. The highest surface-absorbed dose was 24 mGy, but substantial contrast could still be obtained at 7 mGy, indicating potential applicability in medical imaging. The dominant noise contribution in the images stems from the detection system, pointing to a possible decrease in the surface-absorbed dose for an optimized system of more than a factor of 2.
引用
收藏
页码:2911 / 2923
页数:13
相关论文
共 29 条
[1]  
Bevington P., 2002, Data Reduction and Error Analysis for the Physical Sciences, V3rd ed.
[2]  
Browne J. A., 1993, SNARK93 PROGRAMMING
[3]   A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[4]   XOP: A multiplatform graphical user interface for synchrotron radiation spectral and optics calculations. [J].
del Rio, MS ;
Dejus, RJ .
MATERIALS, MANUFACTURING, AND MEASUREMENT FOR SYNCHROTRON RADIATION MIRRORS, 1997, 3152 :148-157
[5]   MEASUREMENT OF SMALL-ANGLE PHOTON SCATTERING FOR SOME BREAST TISSUES AND TISSUE SUBSTITUTE MATERIALS [J].
EVANS, SH ;
BRADLEY, DA ;
DANCE, DR ;
BATEMAN, JE ;
JONES, CH .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :7-18
[6]   NOISE AND CONTRAST DETECTION IN COMPUTED-TOMOGRAPHY IMAGES [J].
FAULKNER, K ;
MOORES, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (04) :329-339
[7]   THE EFFECT OF FAT ON THE COHERENT-TO-COMPTON SCATTERING RATIO IN THE CALCANEUS - A COMPUTATIONAL ANALYSIS [J].
GUTTMANN, GD ;
GOODSITT, MM .
MEDICAL PHYSICS, 1995, 22 (08) :1229-1234
[8]   Two-dimensional detector software: From real detector to idealised image or two-theta scan [J].
Hammersley, AP ;
Svensson, SO ;
Hanfland, M ;
Fitch, AN ;
Hausermann, D .
HIGH PRESSURE RESEARCH, 1996, 14 (4-6) :235-248
[9]   X-RAY-DIFFRACTION COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
MEDICAL PHYSICS, 1987, 14 (04) :515-525
[10]   ELASTIC SCATTER COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (02) :183-186