Computer assisted diabetes care: A 6-year retrospective

被引:36
作者
Lehmann, ED
Deutsch, T
机构
[1] ST BARTHOLOMEWS HOSP, ACAD DEPT RADIOL, LONDON, ENGLAND
[2] SEMMELWEIS UNIV MED, CTR INFORMAT TECHNOL, H-1085 BUDAPEST, HUNGARY
基金
英国惠康基金;
关键词
diabetes mellitus; dynamic simulation; modelling; education; insulin dosage adjustment;
D O I
10.1016/0169-2607(96)01751-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Over the past 6 years we have designed a number of computer-based prototypes for the provision of therapeutic advice and the generation of glycaemic predictions in insulin-dependent (type 1) diabetic patients. In this paper we provide an overview of some of this work, and describe our experiences in trying to develop such methods for clinical use. We review, as an example,a model of the glucoregulatory system which has been developed for patient and medical staff education about type 1 diabetes mellitus, as well as possibly for therapeutic use. Using individualised parameter values the predictions of the model can be applied to generate 24-h simulations of patient blood glucose profiles. Previous preliminary retrospective validation work performed with this model has revealed a mean predictive accuracy for blood glucose simulations of approximately 2 mmol/l. Conceptual limitations of such modelling approaches are considered. We comment that such ' mechanistic ' models may lack the necessary sophistication and flexibility to represent the complexity of the human glucoregulatory system and the challenges it has to face. Although such methodologies may therefore not be suitable for safe and effective application in routine clinical practice, we conclude that the evolution of such a system for demonstration/educational purposes could have widespread clinical utility as an interactive teaching tool.
引用
收藏
页码:209 / 230
页数:22
相关论文
共 66 条
[1]  
ALBISSER AM, 1989, CRIT REV BIOMED ENG, V17, P1
[2]   INSULIN DOSAGE ADJUSTMENT USING MANUAL METHODS AND COMPUTER ALGORITHMS - A COMPARATIVE-STUDY [J].
ALBISSER, AM ;
SCHIFFRIN, A ;
SCHULZ, M ;
TIRAN, J ;
LEIBEL, BS .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (06) :577-584
[3]   A PROBABILISTIC APPROACH TO GLUCOSE PREDICTION AND INSULIN DOSE ADJUSTMENT - DESCRIPTION OF METABOLIC MODEL AND PILOT EVALUATION STUDY [J].
ANDREASSEN, S ;
BENN, JJ ;
HOVORKA, R ;
OLESEN, KG ;
CARSON, ER .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 41 (3-4) :153-165
[4]  
ANDREASSEN S, 1994, P COMPUTERS DIABETES, P28
[5]  
ANDREASSEN S, 1990, REPORT DEV PROTOTYPE, P15
[6]  
[Anonymous], 1990, Diabet Med, V7, P360
[7]   COMPUTER-SIMULATION OF PLASMA-INSULIN AND GLUCOSE DYNAMICS AFTER SUBCUTANEOUS INSULIN INJECTION [J].
BERGER, M ;
RODBARD, D .
DIABETES CARE, 1989, 12 (10) :725-736
[8]   IMPACT OF COMPUTER-SIMULATION ON DIABETES RESEARCH AND PRACTICE [J].
BERGMAN, RN ;
BUCHANAN, TA .
DIABETES CARE, 1989, 12 (10) :748-749
[9]  
BEYER J, P 1 INT S COMP SYST
[10]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310