The effect of diffusion and susceptibility differences on T-2 measurements for fluids in porous media and biological tissues

被引:20
作者
Borgia, GC [1 ]
Brown, RJS [1 ]
Fantazzini, P [1 ]
机构
[1] UNIV BOLOGNA,DEPT ICMTA,I-40136 BOLOGNA,ITALY
关键词
T-2; relaxation; diffusion; susceptibility differences in porous media;
D O I
10.1016/S0730-725X(96)00157-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A number of features of T-2 measurements for fluids in porous media have shown behavior contrary to that suggested by intuition developed in other areas, For porous media with relatively uniform pore spaces the following have been observed, in each case for certain ranges only of chi(nu) (susceptibility difference times frequency), D (diffusion coefficient), a (a pore dimension), porespace shape and distribution, echo-time tau for single echoes and half-echo-spacing tau for CPMG): (1) In S(t) for FID (free induction decay, S for signal) with constant slope after an initial period of increasing slope; (2) In S(t) for single (subscript s) echoes linear (instead of cubic) in t after an initial period; (3) for CPMG R(tau) = 1/T-2(tau) - 1/T-2(tau --> 0) linear in tau over a substantial range; (4) slope of R(tau) independent of D and a for this range; (5) slope R(s) of In S-s(t) independent of D and a, and (6) R(s)(t) and R(tau) at long times linear (instead of quadratic) in chi(nu). These features appear to be compatible with the assumption of a truncated Cauchy-Lorentz distribution of the local magnetic fields due to susceptibility differences. The statistics of repeated sampling of local fields in different parts of the porespace during diffusion lead to a suppression, after a short time, of the effects of diffusion on the FID decay rate and the single-echo decay rate over significant ranges of the parameters, Data are presented to extend the range of parameters studied previously. Copyright (C) 1996 Elsevier Science Inc.
引用
收藏
页码:731 / 736
页数:6
相关论文
共 11 条
[1]  
BERGMAN DJ, IN PRESS PHYS REV E
[2]   SCALING OF SPIN-ECHO AMPLITUDES WITH FREQUENCY, DIFFUSION-COEFFICIENT, PORE-SIZE, AND SUSCEPTIBILITY DIFFERENCE FOR THE NMR OF FLUIDS IN POROUS-MEDIA AND BIOLOGICAL TISSUES [J].
BORGIA, GC ;
BROWN, RJS ;
FANTAZZINI, P .
PHYSICAL REVIEW E, 1995, 51 (03) :2104-2114
[3]   DISTRIBUTION OF FIELDS FROM RANDOMLY PLACED DIPOLES - FREE-PRECESSION SIGNAL DECAY AS RESULT OF MAGNETIC GRAINS [J].
BROWN, RJ .
PHYSICAL REVIEW, 1961, 121 (05) :1379-+
[4]   PROBLEMS IN IDENTIFYING MULTIMODAL DISTRIBUTIONS OF RELAXATION-TIMES FOR NMR IN POROUS-MEDIA [J].
BROWN, RJS ;
BORGIA, GC ;
FANTAZZINI, P ;
MESINI, E .
MAGNETIC RESONANCE IMAGING, 1991, 9 (05) :687-693
[5]   SOME CONTRAST AGENTS IN OILWELL LOGGING AND IN MEDICAL MRI [J].
BROWN, RJS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :551-552
[6]   MR CONTRAST DUE TO MICROSCOPICALLY HETEROGENEOUS MAGNETIC-SUSCEPTIBILITY - NUMERICAL SIMULATIONS AND APPLICATIONS TO CEREBRAL PHYSIOLOGY [J].
FISEL, CR ;
ACKERMAN, JL ;
BUXTON, RB ;
GARRIDO, L ;
BELLIVEAU, JW ;
ROSEN, BR ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :336-347
[7]   ON THE TRANSVERSE RELAXATION RATE ENHANCEMENT INDUCED BY DIFFUSION OF SPINS THROUGH INHOMOGENEOUS FIELDS [J].
HARDY, P ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :348-356
[8]   DECAY OF NUCLEAR MAGNETIZATION BY DIFFUSION IN A PARABOLIC MAGNETIC-FIELD - AN EXACTLY SOLVABLE MODEL [J].
LEDOUSSAL, P ;
SEN, PN .
PHYSICAL REVIEW B, 1992, 46 (06) :3465-3485
[9]   DIFFUSION PROPAGATOR AS A PROBE OF THE STRUCTURE OF POROUS-MEDIA [J].
MITRA, PP ;
SEN, PN ;
SCHWARTZ, LM ;
LEDOUSSAL, P .
PHYSICAL REVIEW LETTERS, 1992, 68 (24) :3555-3558
[10]   TRANSVERSE RELAXIVITY OF PARTICULATE MRI CONTRAST-MEDIA - FROM THEORIES TO EXPERIMENTS [J].
MULLER, RN ;
GILLIS, P ;
MOINY, F ;
ROCH, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :178-182