Proteomics: a technology-driven and technology-limited discovery science

被引:90
作者
Lee, KH [1 ]
机构
[1] Cornell Univ, Ithaca, NY 14853 USA
关键词
D O I
10.1016/S0167-7799(01)01639-0
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An emerging field for the analysis of biological systems is the study of the complete protein complement of the genome, the 'proteome'. There are several complementary tools available for proteome analysis including 2D protein electrophoresis and mass spectrometry. Emerging technologies for proteome analysis include spotted-array-based methods and microfluidic devices. Taken together, these technologies provide a wealth of information that is useful in discovery-based science. However, there are some key limitations of these approaches and new technology is required to be able to fully integrate proteomic information with information obtained about DNA sequence, mRNA profiles and metabolite concentrations into effective models of biological systems.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 52 条
[1]   INTERNAL AMINO-ACID SEQUENCE-ANALYSIS OF PROTEINS SEPARATED BY ONE-DIMENSIONAL OR TWO-DIMENSIONAL GEL-ELECTROPHORESIS AFTER INSITU PROTEASE DIGESTION ON NITROCELLULOSE [J].
AEBERSOLD, RH ;
LEAVITT, J ;
SAAVEDRA, RA ;
HOOD, LE ;
KENT, SBH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1987, 84 (20) :6970-6974
[2]   A comparison of selected mRNA and protein abundances in human liver [J].
Anderson, L ;
Seilhamer, J .
ELECTROPHORESIS, 1997, 18 (3-4) :533-537
[3]   Toward a clinical molecular scanner for proteome research: Parallel protein chemical processing before and during western blot [J].
Bienvenut, WV ;
Sanchez, JC ;
Karmime, A ;
Rouge, V ;
Rose, K ;
Binz, PA ;
Hochstrasser, DF .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4800-4807
[4]   A molecular scanner to automate proteomic research and to display proteome images [J].
Binz, PA ;
Müller, M ;
Walther, D ;
Bienvenut, WV ;
Gras, R ;
Hoogland, C ;
Bouchet, G ;
Gasteiger, E ;
Fabbretti, R ;
Gay, S ;
Palagi, P ;
Wilkins, MR ;
Rouge, V ;
Tonella, L ;
Paesano, S ;
Rossellat, G ;
Karmime, A ;
Bairoch, A ;
Sanchez, JC ;
Appel, RD ;
Hochstrasser, DF .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4981-4988
[5]   A NONLINEAR WIDE-RANGE IMMOBILIZED PH GRADIENT FOR 2-DIMENSIONAL ELECTROPHORESIS AND ITS DEFINITION IN A RELEVANT PH SCALE [J].
BJELLQVIST, B ;
PASQUALI, C ;
RAVIER, F ;
SANCHEZ, JC ;
HOCHSTRASSER, D .
ELECTROPHORESIS, 1993, 14 (12) :1357-1365
[6]  
Choe LH, 2000, ELECTROPHORESIS, V21, P993, DOI 10.1002/(SICI)1522-2683(20000301)21:5<993::AID-ELPS993>3.0.CO
[7]  
2-9
[8]   Antibody arrays for high-throughput screening of antibody-antigen interactions [J].
de Wildt, RMT ;
Mundy, CR ;
Gorick, BD ;
Tomlinson, IM .
NATURE BIOTECHNOLOGY, 2000, 18 (09) :989-994
[9]   Proteomic analysis [J].
Dutt, MJ ;
Lee, KH .
CURRENT OPINION IN BIOTECHNOLOGY, 2000, 11 (02) :176-179
[10]  
Futcher B, 1999, MOL CELL BIOL, V19, P7357