Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system

被引:53
作者
Westmore, MS
Fenster, A
Cunningham, IA
机构
[1] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON N6A 5C1,CANADA
[2] LONDON HLTH SCI CTR,DEPT DIAGNOST RADIOL,LONDON,ON N6A 4G5,CANADA
关键词
coherent scatter; x-ray diffraction; bone-mineral content (BMC);
D O I
10.1118/1.597720
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Low-angle scatter of x rays at diagnostic energies is primarily coherent. This coherence gives rise to interference effects resulting in x-ray diffraction patterns that are characteristic of the scattering material, A method is described of imaging these low-angle (0 degrees-10 degrees) x-ray diffraction properties of tissue specimens using a diagnostic x-ray beam and image intensifier-based system. The coherent-scatter cross sections of several materials measured this way are presented. It is shown theoretically that the measurements made with this system can be expressed as the mono-energetic cross section ''blurred'' by the x-ray spectrum using a linear superposition integral. Experimental results using aluminum powder confirm this. Using a 70 kVp x-ray beam filtered with gadolinium to reduce the spectral width, materials such as water, Lucite, and hydroxyapatite all have significantly different diffraction patterns. The cross sections determined from this analysis form the basis of a unique method of characterizing and identifying tissue samples according to their atomic structure rather than x-ray attenuation properties. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:723 / 733
页数:11
相关论文
共 24 条
[1]   QUANTITATIVE MEASUREMENT OF SMALL-ANGLE GAMMA-RAY SCATTERING FROM WATER, NYLON, AND LUCITE [J].
BRADLEY, DA ;
DANCE, DR ;
EVANS, SH ;
JONES, CH .
MEDICAL PHYSICS, 1989, 16 (06) :851-857
[2]   IMAGE INTENSIFIER DISTORTION CORRECTION [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1987, 14 (02) :249-252
[3]  
Cullity B.D., 1956, ELEMENTS XRAY DIFFRA, P123
[4]   MEASUREMENT OF SMALL-ANGLE PHOTON SCATTERING FOR SOME BREAST TISSUES AND TISSUE SUBSTITUTE MATERIALS [J].
EVANS, SH ;
BRADLEY, DA ;
DANCE, DR ;
BATEMAN, JE ;
JONES, CH .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :7-18
[5]   STATUS AND OUTLOOK OF COHERENT-X-RAY SCATTER IMAGING [J].
HARDING, G ;
KOSANETZKY, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) :933-944
[6]   X-RAY-DIFFRACTION COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
MEDICAL PHYSICS, 1987, 14 (04) :515-525
[7]   ELASTIC SCATTER COMPUTED-TOMOGRAPHY [J].
HARDING, G ;
KOSANETZKY, J ;
NEITZEL, U .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (02) :183-186
[8]  
HARDING G, 1987, AGEING SPINE, P157
[9]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[10]  
HUKINS DWL, 1981, XRAY DIFFRACTION DIS, P7