Applicability of the PEMS technique for simplified NOX monitoring on board ships

被引:12
作者
Cooper, DA [1 ]
Ekström, M [1 ]
机构
[1] Swedish Environm Res Inst Ltd, IVL, S-40014 Gothenburg, Sweden
关键词
NOx; emissions; monitoring; PEMS; ship;
D O I
10.1016/j.atmosenv.2004.09.019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of a predictive emission monitoring system (PEMS) as a technique for NOx monitoring on medium speed marine diesel engines has been evaluated for 16 similar engines on four different ships. The PEMS function tested measured O-2 concentration in the exhaust gas, engine load, combustion air temperature and humidity. and barometric pressure to calculate the NOx concentration. Emission measurements were carried out by means of a conventional continuous emission monitoring system (CEMS) and the measured NOx concentrations were compared with those calculated by the PEMS function. For 11 of the 16 engines, the average error between measured and calculated NOx concentration was < 10% of the calibration range (1725 ppm). In addition, 10 of the engines displayed correlation coefficients between measured and calculated NOx as 0.90 or higher. For two of the ships, the predicted NOx concentrations from all engines on board gave good agreement with those measured (2.6-4.7% and 2.6-8.0% average error). In other cases however. the performance of the PEMS function was poor e.g. the four engines of ship D showed aver-age errors of 10.3-17.7%. Although similar engine models, fuel and load characteristics were compared in the tests. the specific NOx emissions at steady-state loads used varied from 12.6 up to 15.8 g k(-1)Wh(corr). Although a single PEMS function may prove universal and adequate for calculating NOx emissions from similar engines on board the same ship, an engine specific PEMS function is recommended. The form of the PEMS function, i.e. usinLy exhaust O-2 and engine load as inputs. is however likely to be applicable to most propeller-law diesel engines. Bearing in mind the performance criteria for using PEMS at land-based installations. the results from this study are promising. Viewed as a single data set of 56 h with 16 separate engine comparisons between CEMS and PEMS. the data set shows a relative accuracy of 14.5% i.e. within the 20% requirement of the US Environmental Protection Agency. In light of the increased interest and international guidelines for continuous NOx monitoring on board ships, the PEMS technique can offer a simple but cost-effective option. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 20 条
[1]  
BROOKMAN CS, 1996, IMAS 96 OCT
[2]   A feasibility study on the predictive emission monitoring system applied to the Hsinta power plant of Taiwan power company [J].
Chien, TW ;
Chu, H ;
Hsu, WC ;
Tseng, TK ;
Hsu, CH ;
Chen, KY .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (08) :1022-1028
[3]   Predictive NOx emission monitoring on board a passenger ferry [J].
Cooper, DA ;
Andreasson, K .
ATMOSPHERIC ENVIRONMENT, 1999, 33 (28) :4637-4650
[4]   Updated emissions from ocean shipping [J].
Corbett, JJ ;
Koehler, HW .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D20)
[5]   Thoughts on predictive emissions monitoring from a regulatory perspective [J].
Eghneim, G .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (11) :1086-1092
[6]   Emission from international sea transportation and environmental impact -: art. no. 4560 [J].
Endresen, O ;
Sorgård, E ;
Sundet, JK ;
Dalsoren, SB ;
Isaksen, ISA ;
Berglen, TF ;
Gravir, G .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D17)
[7]  
*EUR COMM, 2002, EUR STRAT RED ATM EM
[8]  
HARRISON D, 2003, EVALUATION MARKET BA
[9]  
*INT MAR ORG, 2003, ANNEX 5 RESOLUTION M, V103
[10]  
*INT MAR ORG, 1998, IMO664E