A colorimetric method for fluoride determination in aqueous samples based on the hydroxyl deprotection reaction of a cyanine dye

被引:73
作者
Zhu, CQ
Chen, JL
Zheng, H
Wu, YQ
Xu, JG [1 ]
机构
[1] Xiamen Univ, Dept Chem, Key Lab Analyt Sci MOE, Xiamen 361005, Peoples R China
[2] Anhui Normal Univ, Coll Chem & Mat Sci, Wuhan 241000, Peoples R China
基金
中国国家自然科学基金;
关键词
fluoride ion; cyanine; hydroxyl deprotection reaction; colorimetric method;
D O I
10.1016/j.aca.2005.03.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new highly sensitive and selective colorimetric method for fluoride determination in water is described. The novel reagent for this method is a cyanine dye (C-1) on which the hydroxyl group has been protected by reaction with tert-butyldimethylsilane (TBS) to form the silanated dye, C-2. C-2 is selectively attacked by fluoride ions to reform C-1. C-1 has an absorption maximum at 600 nm with a molar absorptivity of about 200,000. Under optimized conditions, absorbance at 600 nm is proportional to fluoride concentration up to about 1 x 10(-4) mol/L with a detection limit of 1.0 x 10(-7) mol/L. Because of the specific affinity of fluoride for the TBS functional group on C-2, there is little interference by other ions. The method has been successfully applied for fluoride determinations in local rainwater samples. Results determined by the proposed method agree favorably with those determined by a fluoride ion selective electrode method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 316
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 1998, STANDARD METHODS EXA, DOI DOI 10.2-10.30
[2]  
*ASTM, 2003, D117999 ASTM
[3]   RAPID PHOTOMETRIC DETERMINATION OF FLUORIDE IN WATER - USE OF SODIUM 2-(PARA-SULFOPHENYLAZO)-1,8-DIHYDROXYNAPHTHALENE-3,6-DISULFONATE-ZIRCONIUM LAKE [J].
BELLACK, E ;
SCHOUBOE, PJ .
ANALYTICAL CHEMISTRY, 1958, 30 (12) :2032-2034
[4]  
BLAZSEKBODO A, 1971, P 2 C APPL PHYS CHEM, V1, P25
[5]  
BLAZSEKBODO A, 1974, FARM BUCHUREST, V22, P34
[6]   Isotachophoresis and isotachophoresis -: zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection [J].
Bodor, R ;
Madajová, V ;
Kaniansky, D ;
Masár, M ;
Jöhnck, M ;
Stanislawski, B .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :155-165
[7]   OFF-LINE AND ONLINE DETERMINATION OF FLUORIDE WITH UNSEGMENTED FLOW CONFIGURATIONS [J].
CHEN, DH ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :137-143
[8]   A new method for fluoride determination by using fluorophores and dyes anchored onto MCM-41 [J].
Descalzo, AB ;
Jiménez, D ;
El Haskouri, J ;
Beltrán, D ;
Amorós, P ;
Marcos, MD ;
Martínez-Máñez, R ;
Soto, J .
CHEMICAL COMMUNICATIONS, 2002, (06) :562-563
[9]   Extraction-spectrophotometric method for determination of fluoride in the range of microgram per liter in natural waters [J].
Faraj-Zadeh, MA ;
Kalhor, EG .
MIKROCHIMICA ACTA, 2001, 137 (3-4) :169-171
[10]   ELECTRODE FOR SENSING FLUORIDE ION ACTIVITY IN SOLUTION [J].
FRANT, MS ;
ROSS, JW .
SCIENCE, 1966, 154 (3756) :1553-&