Fully-automated spectrophotometric method for measurement of antioxidant activity of catalase

被引:65
作者
Slaughter, MR [1 ]
O'Brien, PJ [1 ]
机构
[1] SmithKline Beecham Pharmaceut, Safety Assessment, Welwyn Garden City AL6 9AR, Herts, England
关键词
catalase; automated analayser; catalatic activity; hydrogen peroxide; erythrocytes; Trinder reagent; uricase; rat liver;
D O I
10.1016/S0009-9120(00)00158-2
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Develop fully automated assay of antioxidant catalatic activity of catalase. Design and methods: The assay is based on standard, clinical chemistry automated analyzer methods for measuring hydrogen peroxide by using the Trinder reagent. Catalase competes with 324 U/L horseradish peroxidase (type XII) and Trinder reagent for hydrogen peroxide produced by 46 U/L uricase action on urate. Unit activity is defined as 50% inhibition of maximal color development. Results: Within-run coefficients of variation (cv) were 2% for standards and samples, whereas between-run cv was 3.1% for standards and 7.3% for samples. Dilutional parallelism and linearity were demonstrated for 8-fold dilutions of samples over the range 0.1 to 1.1 U/mL. Recovery of added catalase was complete. Samples are stable to freezing and storage for 1 week at -80 degreesC. Activities (units/mL) ranged from 0.29 to 0.41 in human and canine plasma, and for erythrocytes from 48 to 70 in man, 17 to 19 in dogs, and 60 to 89 in rats. Rat liver activity (units/g wet weight) was age-dependent and ranged from 17 to 24 at 2 months, and from 19 to 37 at 6 months. Conclusion: The first, fully automated assay for the measurement of catalatic activity of catalase in plasma, erythrocytes, and liver is demonstrated for multiple species. The assay is simple, precise, relatively inexpensive, and rapid. Copyright (C) 2000 The Canadian Society of Clinical Chemists.
引用
收藏
页码:525 / 534
页数:10
相关论文
共 63 条
[1]  
AEBI H., 1983, METHODS ENZYMATIC AN, V3
[2]   IMPROVED COLOR REAGENT FOR DETERMINATION OF BLOOD-GLUCOSE BY OXIDASE SYSTEM [J].
BARHAM, D ;
TRINDER, P .
ANALYST, 1972, 97 (1151) :142-&
[3]  
BEERS RF, 1952, J BIOL CHEM, V195, P133
[4]   MEASUREMENT OF CATALASE ACTIVITY IN TISSUE EXTRACTS [J].
COHEN, G ;
DEMBIEC, D ;
MARCUS, J .
ANALYTICAL BIOCHEMISTRY, 1970, 34 (01) :30-+
[5]   A modified catalase assay suitable for a plate reader and for the analysis of brain cell cultures [J].
Cohen, G ;
Kim, M ;
Ogwu, V .
JOURNAL OF NEUROSCIENCE METHODS, 1996, 67 (01) :53-56
[6]  
FOSSATI P, 1983, CLIN CHEM, V29, P1494
[7]  
FOSSATI P, 1980, CLIN CHEM, V26, P227
[8]  
FOSSATI P, 1982, CLIN CHEM, V28, P2077
[9]  
Fossati P, 1978, Quad Sclavo Diagn, V14, P164
[10]  
Goldberg D.M., 1983, Methods of Enzymatic Analysis, V3, P258