Modeling a Direct Contact Heat Exchanger used in a supercritical water loop

被引:11
作者
Cascella, F. [1 ]
Teyssedou, A. [1 ]
机构
[1] Polytech Montreal, Nucl Engn Inst, Dept Engn Phys, Stn Ctr Ville, Montreal, PQ H3C 3A7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Direct Contact Heat Exchanger; Droplet statistics; Nozzle spray; Convection; Evaporation; SIZE-DISTRIBUTION ANALYSIS; ROSIN-RAMMLER; CONDENSATION; SPRAY; STEAM;
D O I
10.1016/j.applthermaleng.2014.11.033
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
In the last thirty years, Direct Contact Heat Exchangers (DCHX) have found a great success in different power engineering applications. In fact, due to the direct contact of hot and cold working fluids, it is possible to reach very high mass and energy transfer efficiencies. Despite their high performance, it is still difficult to predict the correct heat transfer as a function of plant operating conditions. Thus, this paper concerns the study of a DCHX used in a supercritical water test facility. It consists of a vessel where superheated steam is cooled by mixing it with sub-cooled water via a nozzle that sprays the fluid under the form of tiny droplets. A thermodynamic model which includes the statistical distribution of droplets and their temperature evolution is presented. To this aim, a Cumulative Distribution Function (CDF) based on Rosin-Rammler's equation is used. To evaluate both convection and evaporation energy transfer, the evolution of the velocity of the droplet as function their size is studied. A comparison of model's predictions with experimental data, for steam pressures of 1.6 and 2.1 MPa, shows reasonable good agreement. At higher pressures the model over predicts the experimental trends. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 15 条
[1]
[Anonymous], 2017, Atomization and Sprays
[2]
Ashgriz N, 2011, HANDBOOK OF ATOMIZATION AND SPRAYS: THEORY AND APPLICATIONS, P1, DOI 10.1007/978-1-4419-7264-4
[3]
Baehr H.D., 2006, Heat and Mass Transfer
[4]
On the development of spray submodels based on droplet size moments [J].
Beck, JC ;
Watkins, AP .
JOURNAL OF COMPUTATIONAL PHYSICS, 2002, 182 (02) :586-621
[5]
Cascella F., 2013, P 2013 CAN NUCL SOC
[6]
DIRECT CONTACT CONDENSATION OF STEAM ON DROPLETS [J].
CELATA, GP ;
CUMO, M ;
DANNIBALE, F ;
FARELLO, GE .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1991, 17 (02) :191-211
[7]
A modified Nukiyama-Tanasawa distribution function and a Rosin-Rammler model for the particle-size-distribution analysis [J].
Gonzalez-Tello, P. ;
Camacho, F. ;
Vicaria, J. M. ;
Gonzalez, P. A. .
POWDER TECHNOLOGY, 2008, 186 (03) :278-281
[8]
Application of the Rosin-Rammler and Gates-Gaudin-Schuhmann models to the particle size distribution analysis of agglomerated cork [J].
Macías-García, A ;
Cuerda-Correa, EM ;
Díaz-Díez, MA .
MATERIALS CHARACTERIZATION, 2004, 52 (02) :159-164
[9]
MARSHALL W.R., 1955, Transaction of ASME, P1377
[10]
Experimental study of abrupt discharge of water at supercritical conditions [J].
Muftuoglu, Altan ;
Teyssedou, Alberto .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 55 :12-20