Conjugated polythiophene probes target lysosome-related acidic vacuoles in cultured primary cells

被引:35
作者
Bjork, Per [1 ]
Nilsson, K. Peter R.
Lenner, Liselotte
Kagedal, Bertil
Persson, Birgitta
Inganas, Olle
Jonasson, Jon
机构
[1] Linkoping Univ, IFM, SE-58183 Linkoping, Sweden
[2] Linkoping Univ Hosp, Div Clin Chem, Dept Biomed & Surg, SE-58185 Linkoping, Sweden
[3] Linkoping Univ Hosp, LMC, SE-58185 Linkoping, Sweden
关键词
conjugated polyelectrolyte; polythiophene; fibroblast; lysosome; cancer;
D O I
10.1016/j.mcp.2007.04.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conformation-sensitive optical probes for studying biological processes and structures are of great interest. The present work shows for the first time that conjugated polyelectrolyte (CPE) probes can be used for specific targeting of chromatin, nuclear and cytoplasmatic vesicles, and cytoskeletal components in a complex system of cultured cells. One of the probes could also be used for vital staining of live cells. When bound to different entities, the polythiophene derivative probes emitted light with different colors due to the unique spectral properties of these conformation sensitive probes. The physical pre-requisites for binding could also be exploited for characterization of the target. Unexpectedly, lysosome-related acidic vacuoles were targeted in cultured primary cells by both anionic, cationic, and zwitterionic polythiophene derivatives. Pre-treatment with Bafilomycin At, a specific inhibitor of vacuolar-type H+-ATPase, caused redistribution of the staining. The targeting of lysosome-related acidic vesicles could not be demonstrated in transformed cells (melanoma, neuroblastoma, and prostate cancer cell lines), indicating a difference in the localization, structure, accessibility, or quantity of the target in cultured normal cells as compared with the malignant cell lines. The chemical nature of the conjugated polyelectrolyte complex in the cytoplasmatic vacuoles remains elusive. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:329 / 337
页数:9
相关论文
共 38 条
[1]  
Allison A C, 1974, J Clin Pathol Suppl (R Coll Pathol), V7, P43
[2]  
ANDERSSON M, 1991, POLYM COMMUN, V32, P546
[3]   The Arf-family protein, Arl8b, is involved in the spatial distribution of lysosomes [J].
Bagshaw, Richard D. ;
Callahan, John W. ;
Mahuran, Don J. .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2006, 344 (04) :1186-1191
[4]   Highly sensitive biological and chemical sensors based on reversible fluorescence quenching in a conjugated polymer [J].
Chen, LH ;
McBranch, DW ;
Wang, HL ;
Helgeson, R ;
Wudl, F ;
Whitten, DG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (22) :12287-12292
[5]   Actin filaments and myosin I alpha cooperate with microtubules for the movement of lysosomes [J].
Cordonnier, MN ;
Dauzonne, D ;
Louvard, D ;
Coudrier, E .
MOLECULAR BIOLOGY OF THE CELL, 2001, 12 (12) :4013-4029
[6]   Solvent and mutation effects on the nucleation of amyloid β-protein folding [J].
Cruz, L ;
Urbanc, B ;
Borreguero, JM ;
Lazo, ND ;
Teplow, DB ;
Stanley, HE .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (51) :18258-18263
[7]   Exosome secretion:: The art of reutilizing nonrecycled proteins? [J].
de Gassart, A ;
Géminard, C ;
Hoekstra, D ;
Vidal, M .
TRAFFIC, 2004, 5 (11) :896-903
[8]   Photovoltaic cells with a conjugated polyelectrolyte [J].
Ding, L ;
Jonforsen, M ;
Roman, LS ;
Andersson, MR ;
Inganäs, O .
SYNTHETIC METALS, 2000, 110 (02) :133-140
[9]   Fluorescent polymeric transducer for the rapid, simple, and specific detection of nucleic acids at the zeptomole level [J].
Doré, K ;
Dubus, S ;
Ho, HA ;
Lévesque, I ;
Brunette, M ;
Corbeil, G ;
Boissinot, M ;
Boivin, G ;
Bergeron, MG ;
Boudreau, D ;
Leclerc, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (13) :4240-4244
[10]   Responsive supramolecular polythiophene assemblies [J].
Faïd, K ;
Leclerc, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (21) :5274-5278