Promise and challenges of bioabsorbable stents

被引:81
作者
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
stents; thrombosis; restenosis;
D O I
10.1002/ccd.21176
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Despite the development and progression of metallic stents, many concerns still remain because of their permanent nature. Although metallic stents are effective in preventing recoil and late restenosis after coronary angioplasty, they continue to have limitations such as stent thrombosis and mismatch of the stent to the vessel size. Thus, the concept of bioabsorbable stents has emerged as an alternative to permanent metal stents. This review will outline concepts, material designs, preclinical, and initial clinical experimental studies with bioabsorbable stents. (C) 2007 Wiley-Liss, Inc.
引用
收藏
页码:407 / 414
页数:8
相关论文
共 24 条
[1]
Development of a new biodegradable intravascular polymer stent with simultaneous incorporation of bioactive substances [J].
Blindt, R ;
Hoffmeister, KM ;
Bienert, H ;
Pfannschmitt, O ;
Bartsch, G ;
Thissen, H ;
Klee, D ;
Vom Dahl, J .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (12) :843-853
[2]
Bosiers M, 2006, J CARDIOVASC SURG, V47, P171
[3]
CAPEK J, 2006, P CRT
[4]
ERBEL R, 2006, P ACC
[5]
A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[6]
HASTINGS GW, 1992, CARDIVASCULAR BIOMAT
[7]
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? [J].
Heublein, B ;
Rohde, R ;
Kaese, V ;
Niemeyer, M ;
Hartung, W ;
Haverich, A .
HEART, 2003, 89 (06) :651-656
[8]
Konig Andreas, 2002, Z Kardiol, V91 Suppl 3, P98
[9]
Murphy J G, 1991, J Invasive Cardiol, V3, P144
[10]
LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF A BALLOON-EXPANDABLE STENT IN THE NATIVE CORONARY CIRCULATION [J].
SAVAGE, MP ;
FISCHMAN, DL ;
SCHATZ, RA ;
TEIRSTEIN, PS ;
LEON, MB ;
BAIM, D ;
ELLIS, SG ;
TOPOL, EJ ;
HIRSHFELD, JW ;
CLEMAN, MW ;
BUCHBINDER, M ;
BAILEY, S ;
HEUSER, R ;
WALKER, CM ;
CURRY, RC ;
GEBHARDT, S ;
RAKE, R ;
GOLDBERG, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1207-1212