Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods

被引:15
作者
Chowdhury, TA [1 ]
Dyer, PH
Bartlett, WA
Legge, ES
Durbin, SM
Barnett, AH
Bain, SC
机构
[1] Birmingham Heartlands Hosp, Dept Med, Birmingham B9 5SS, W Midlands, England
[2] Birmingham Heartlands Hosp, Dept Clin Chem, Birmingham B9 5SS, W Midlands, England
关键词
glomerular filtration rate; iohexol; plasma clearance;
D O I
10.1016/S0009-8981(98)00116-8
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Use of iohexol clearance has been described as the gold standard for the measurement of glomerular filtration rate (GFR). It is suggested that multiple plasma sampling following iohexol injection is required to accurately determine GFR by area under plasma clearance curve. The aim of this study was to determine whether single plasma sampling 4 h after injection of iohexol could accurately determine GFR in diabetic patients with mild to moderate renal failure, compared to multiple plasma sampling. A total of 120 GFR determinations in 36 patients with non-insulin dependent diabetic renal disease were done over 1 year. No acute deterioration was seen in renal function following injection of contrast in any patient. Strong correlation in GFR measurement was observed between the multiple plasma sampling method and the single plasma sampling method (r(2) = 0.975). Single plasma sampling 4 h after bolus injection of iohexol is a safe and accurate method of determining GFR and change in GFR in diabetic subjects with mild to moderate renal impairment. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 12 条
[1]  
Apelqvist J, 1996, DIABETIC MED, V13, P487
[2]  
AURELL M, 1994, NEPHROL DIAL TRANSPL, V9, P1222
[3]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[4]   MEASUREMENT OF RENAL-FUNCTION WITH IOHEXOL - A COMPARISON OF IOHEXOL, TC-99M-DTPA, AND CR-51 EDTA CLEARANCE [J].
EFFERSOE, H ;
ROSENKILDE, P ;
GROTH, S ;
JENSEN, LI ;
GOLMAN, K .
INVESTIGATIVE RADIOLOGY, 1990, 25 (07) :778-782
[5]   TIME TO SCRAP CREATININE CLEARANCE [J].
GABRIEL, R .
BRITISH MEDICAL JOURNAL, 1986, 293 (6555) :1119-1120
[6]  
HORNSBY VP, 1996, CLIN RADIOL, V51, P829
[7]   A METHOD FOR THE CALCULATION OF RENAL CLEARANCE BASED ON A SINGLE PLASMA SAMPLE [J].
JACOBSSON, L .
CLINICAL PHYSIOLOGY, 1983, 3 (04) :297-305
[8]  
KRUTZEN E, 1984, J LAB CLIN MED, V104, P955
[9]   THE EFFECT OF ANGIOTENSIN-CONVERTING ENZYME-INHIBITION ON DIABETIC NEPHROPATHY [J].
LEWIS, EJ ;
HUNSICKER, LG ;
BAIN, RP ;
ROHDE, RD .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (20) :1456-1462
[10]  
NEWMAN DJ, 1995, 2 YEAR EXPERIENCE IO