Measurement of surface contact area of the ankle joint

被引:35
作者
Kura, H [1 ]
Kitaoka, HB [1 ]
Luo, ZP [1 ]
An, KN [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Rochester, MN 55905 USA
关键词
ankle; biomechanics; foot; joint; joint contact; range of motion;
D O I
10.1016/S0268-0033(98)00011-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. To determine the distribution of contact area of the ankle joint with axial loading and in positions of maximal dorsiflexion, plantar flexion, supination, and pronation. We also tested the effects of extrinsic tendon loading and arch instability. Design. Nine cadaveric feet were studied in the intact condition and following transection of ligaments to create arch instability. Background. Assessment of ankle contact in various joint positions and degrees of instability is difficult to accomplish with conventional methods. Methods. Displacement of the talus relative to the tibia was measured with a magnetic tracking device and tibiotalar joint contact from proximity calculations of digitized joint surfaces. Results. Contact area did not change significantly from unloaded condition to 667 N load condition in the medial, central, and lateral zones. Central zone contact area decreased in plantar flexion by an average of 324 mm(2) (SD, 165 mm(2)) (P = 0.0004). Medial zone contact area decreased in plantar flexion by a mean of 55 mm(2) (SD, 28 mm(2)) (P = 0.0004), decreased in pronation by an average of 42 mm(2) (SD, 36 mm(2)) (P = 0.0056), and increased in supination by an average of 20 mm(2) (SD, 26 mm(2)) (P = 0.0430). Lateral zone contact decreased in plantar flexion by a mean of 124 mm(2) (SD, 57 mm(2)) (P = 0.0002). Conclusions. In plantar flexion, there was a decrease in contact area. Loading extrinsic tendons to the foot did not significantly increase ankle contact area, but arch instability caused a decrease in central and lateral zone contact area.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 22 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]  
BEAUDOIN AJ, 1991, FOOT ANKLE, V12, P19, DOI 10.1177/107110079101200104
[3]   A COMPREHENSIVE STUDY OF PRESSURE DISTRIBUTION IN THE ANKLE JOINT WITH INVERSION AND EVERSION [J].
CALHOUN, JH ;
ENG, M ;
LI, F ;
LEDBETTER, BR ;
VIEGAS, SF .
FOOT & ANKLE INTERNATIONAL, 1994, 15 (03) :125-133
[4]   A 3-DIMENSIONAL ANATOMICAL MODEL OF THE HUMAN PATELLOFEMORAL JOINT, FOR THE DETERMINATION OF PATELLOFEMORAL MOTIONS AND CONTACT CHARACTERISTICS [J].
HEFZY, MS ;
YANG, H .
JOURNAL OF BIOMEDICAL ENGINEERING, 1993, 15 (04) :289-302
[5]  
Itoi E, 1992, J Shoulder Elbow Surg, V1, P131, DOI 10.1016/1058-2746(92)90090-P
[6]   LOAD-BEARING PATTERN OF THE ANKLE JOINT - CONTACT AREA AND PRESSURE DISTRIBUTION [J].
KIMIZUKA, M ;
KUROSAWA, H ;
FUKUBAYASHI, T .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1980, 96 (01) :45-49
[7]  
LIBOTTE M, 1982, REV CHIR ORTHOP, V68, P299
[8]   Determination of the proximity tolerance for measurement of surface contact areas using a magnetic tracking device [J].
Luo, ZP ;
Niebur, GL ;
An, KN .
JOURNAL OF BIOMECHANICS, 1996, 29 (03) :367-372
[9]   THE JOINT-CONTACT AREA OF THE ANKLE - THE CONTRIBUTION OF THE POSTERIOR MALLEOLUS [J].
MACKO, VW ;
MATTHEWS, LS ;
ZWIRKOSKI, P ;
GOLDSTEIN, SA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03) :347-351
[10]   THE EFFECT OF LOADING ON TIBIOTALAR ALIGNMENT IN CADAVER ANKLES [J].
MICHELSON, JD ;
CLARKE, HJ ;
JINNAH, RH .
FOOT & ANKLE, 1990, 10 (05) :280-284