Misplaced endotracheal tubes by paramedics in an urban emergency medical services system

被引:420
作者
Katz, SH
Falk, JL
机构
[1] Orlando Reg Med Ctr, Dept Emergency Med, Orlando, FL 32806 USA
[2] Univ Florida, Coll Med, Gainesville, FL USA
[3] JFK Med Ctr, Dept Emergency Med, Atlantis, FL USA
关键词
D O I
10.1067/mem.2001.112098
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine the incidence of unrecognized, misplaced endotracheal tubes inserted by paramedics in a large urban, decentralized emergency medical services (EMS) system. Methods: We conducted a prospective, observational study of patients intubated in the field by paramedics before emergency department arrival. During an 8-month period, emergency physicians assessed tube position at ED arrival using a combination of auscultation, end-tidal carbon dioxide (ETCO2) monitoring, and direct laryngoscopy. Results: A total of 108 intubated patients were studied. On arrival in the ED, 25% (27/108) of patients were found to have improperly placed endotracheal tubes. Of the misplaced tubes, 67% (18/27) were found to be in the esophagus, whereas in 33% (9/27), the tip of the tube was found to be in the hypopharynx, above the vocal cords. Of the patients with misplaced tubes noted in the hypopharynx, 33% (3/9) died while in the ED. Far the patients found to have tubes in the hypopharynx, 56% (5/9) had evidence of ETCO2 on ED arrival. For the patients found to have esophageal tube placement on ED arrival, 56% (10/18) died in the ED. Esophageal intubation was associated with an absence of expired CO2 (17/18, 94%) on ED arrival. The sings patient in this subset with a recordable ETCO2 had been nasotracheally intubated with the tip of the endotracheal tube noted in the esophagus while spontaneous respirations were present. On patient arrival to the ED, 63% (68/108) of the patients had direct laryngoscopy in addition to ETCO2 determination. All patients had ETCO2 evaluation performed on arrival. All patients in whom an absence of ETCO2 was demonstrated on patient arrival underwent direct laryngoscopy. In cases in which direct laryngoscopy was not performed, the attending physician documented the ETCO2 in conjunction with the presence of bilateral breath sounds. Conclusion: The incidence of out-of-hospital, unrecognized, misplaced endotracheal tubes in our community is excessively high and may be reflective of the incidence occurring in other communities. Data from other communities are needed to clarify the scope of this alarming issue.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 33 条
[1]  
*ACEP POL STAT, 1995, ANN EMERG MED, V25, P441
[2]  
*AM SOC AN, 1998, STAND BAS AN MON
[3]   ASSESSING THE POSITION OF THE TRACHEAL TUBE THE RELIABILITY OF DIFFERENT METHODS [J].
ANDERSEN, KH ;
HALD, A .
ANAESTHESIA, 1989, 44 (12) :984-985
[4]   A DISPOSABLE END-TIDAL CO2 DETECTOR TO VERIFY ENDOTRACHEAL INTUBATION [J].
ANTON, WR ;
GORDON, RW ;
JORDAN, TM ;
POSNER, KL ;
CHENEY, FW .
ANNALS OF EMERGENCY MEDICINE, 1991, 20 (03) :271-275
[5]  
BIRMINGHAM PK, 1986, ANESTH ANALG, V65, P886
[6]   Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation [J].
Bozeman, WP ;
Hexter, D ;
Liang, HK ;
Kelen, GD .
ANNALS OF EMERGENCY MEDICINE, 1996, 27 (05) :595-599
[7]  
*COMM TRAUM AM COL, 1997, ADV TRAUM LIF SUPP C
[8]  
DELEO BC, 1984, CHEST, V85, P341
[9]   WHEN DOES A GUIDELINE BECOME A STANDARD - THE NEW AMERICAN-SOCIETY-OF-ANESTHESIOLOGISTS GUIDELINES GIVE US A CLUE [J].
GINSBURG, WH .
ANNALS OF EMERGENCY MEDICINE, 1993, 22 (12) :1891-1896
[10]  
GOLDBERG JS, 1990, ANESTH ANALG, V70, P191