Fluid-modulated bipolar radiofrequency ablation:: An ex-vivo evaluation study

被引:27
作者
Bruners, P. [1 ]
Mueller, H. [1 ]
Guenther, R. W. [1 ]
Schmitz-Rode, T. [1 ]
Mahnken, A. H. [1 ]
机构
[1] Aachen Univ Hosp, Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Dept Diagnost Radiol, D-52074 Aachen, Germany
关键词
ablation procedures; interventional; liver;
D O I
10.1080/02841850701843085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The effect of radiofrequency ablation (RFA) can be modulated by fluid injection. Purpose: To evaluate the potential of different fluids to modulate the effect of bipolar RFA in an ex-vivo liver model. Material and Methods: A bipolar RFA system with an internally cooled needle-shaped applicator (20-mm active tip) was used to induce coagulation lesions in ex-vivo porcine liver. Prior to the ablation procedure, 1-ml samples of seven different fluids were injected (0.9% saline, gadopentetate dimeglumine, ioxithalamate, 10% hydroxyethyl starch, 5% glucose, 95% ethanol, distilled water). Each fluid was used for five RF ablations. During the procedure, applied energy, impedance, and time were recorded. Additionally, temperature was measured at a fixed distance of 0.5 and 1.0 cm from the RF probe. Generator output was set to 20 W, as recommended by the vendor. Five ablation procedures without fluid injection served as the reference standard. The lesion diameters were measured, and volume and an efficiency index (coagulation volume/procedure duration) calculated and compared (ANOVA, Student-Newman-Keuls test). Results: In comparison to the reference standard, fluid injection resulted in an enlargement of mean coagulation volume for all fluids. In comparison to RF ablation alone (1.42 +/- 0.33 cm(3)), significant increase (P < 0.001) of lesion size was found using gadopentetate dimeglumine, hydroxyethyl starch, glucose, and ethanol. The largest lesions were generated using preinjection of hydroxyethyl starch. Most energy could be applied after injection of glucose. Comparing the efficiency index, no statistically significant differences were found. Conclusion: Besides the modulation of the electrical conductivity, the increase in thermal conductivity also contributes to the enhancement of RFA by the injection of the tested fluids. Further studies are needed to evaluate this effect for larger injection volumes under in-vivo conditions.
引用
收藏
页码:258 / 266
页数:9
相关论文
共 38 条
[1]   Improved coagulation with saline solution pretreatment during radiofrequency tumor ablation in a canine model [J].
Ahmed, M ;
Lobo, SM ;
Weinstein, J ;
Kruskal, JB ;
Gazelle, GS ;
Halpern, EF ;
Afzal, SK ;
Lenkinski, RE ;
Goldberg, SN .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (07) :717-724
[2]   Fluid-modulated RF ablation:: In-vitro experiments [J].
Bruners, P. ;
Hodenius, M. ;
Guenther, R. W. ;
Schmitz-Rode, T. ;
Mahnken, A. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (04) :380-386
[3]   Multipolar radiofrequency ablation with internally cooled electrodes:: Experimental study in ex vivo bovine liver with mathernatic modeling [J].
Clasen, S ;
Schmidt, D ;
Boss, A ;
Dietz, K ;
Kröber, SM ;
Claussen, CD ;
Pereira, PL .
RADIOLOGY, 2006, 238 (03) :881-890
[4]   Bipolar Radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver -: Prediction of coagulation volume from applied energy [J].
Clasen, Stephan ;
Schmidt, Diethard ;
Dietz, Klaus ;
Boss, Andreas ;
Kroeber, Stefan M. ;
Schraml, Christina ;
Fritz, Jan ;
Claussen, Claus D. ;
Pereira, Philippe L. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (01) :29-36
[5]   Radiofrequency liver ablation: Experimental comparative study of water-cooled versus expandable systems [J].
de Baere, T ;
Denys, A ;
Wood, BJ ;
Lassau, N ;
Kardache, M ;
Vilgrain, V ;
Menu, Y ;
Roche, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (01) :187-192
[6]   Percutaneous radiofrequency ablation of renal cell carcinoma [J].
Gervais, DA ;
Arellano, RS ;
Mueller, PR .
EUROPEAN RADIOLOGY, 2005, 15 (05) :960-967
[7]   CT mapping of the distribution of saline during radiofrequency ablation with perfusion electrodes [J].
Gillams, AR ;
Lees, WR .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (04) :476-480
[8]   Complications after percutaneous saline-enhanced radiofrequency ablation of liver tumors: 3-year experience with 336 patients at a single center [J].
Giorgio, A ;
Tarantino, L ;
de Stefano, G ;
Coppola, C ;
Ferraioli, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (01) :207-211
[9]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P670
[10]   Percutaneous tumor ablation: Increased coagulation by combining radio-frequency ablation and ethanol instillation in a rat breast tumor model [J].
Goldberg, SN ;
Kruskal, JB ;
Oliver, BS ;
Clouse, ME ;
Gazelle, GS .
RADIOLOGY, 2000, 217 (03) :827-831