Speciation of Se(IV) and the selenoamino acids by high-performance liquid chromatography-direct hydride generation-atomic fluorescence spectrometry

被引:38
作者
Ipolyi, I [1 ]
Stefánka, Z [1 ]
Fodor, P [1 ]
机构
[1] Szent Istvan Univ, Dept Appl Chem, H-1118 Budapest, Hungary
基金
匈牙利科学研究基金会;
关键词
speciation; selenoamino acids; hydride generation; atomic fluorescence spectrometry;
D O I
10.1016/S0003-2670(01)00868-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The speciation of selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (SeEt) and Se(IV) was performed by on-line coupling of high-performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS) with hydride generation (HG) as high efficiency sample introduction system. Reversed-phase liquid chromatography was applied to separate the selenium species with 0.01 M ammonium acetate buffer (pH = 4) eluent containing 0.5% (v/v) methanol and 0.1 mol l(-1) of DDAB. The operating conditions for chromatographic separation (gradient elution, run time) and hydride generation (concentration of HCl and NaBH4 solution, argon and hydrogen flow rates) were carefully optimized. The efficiency of hydride generation for all of the four species was measured. Detection limits (DLs) obtained for SeCys, SeMet, SeEt and Se(IV) are 18, 70, 96, and 16 mug l(-1), respectively. The analytical performance of the method was controlled by measuring the selenium content of spiked selenium food supplements. The range of obtained recoveries is 90-110%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:367 / 375
页数:9
相关论文
共 23 条
[1]  
BONELLI L, 1998, CANC PREVENTION CONT, V100, pA351
[2]   Investigations into mild conditions for reduction of Se(VI) to Se(IV) and for hydride generation in determination of selenium by direct current plasma atomic emission spectrometry [J].
Brindle, ID ;
Lugowska, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (02) :163-176
[3]  
CAMARA C, 1995, QUALITY ASSURANCE EN, P237
[4]   Sample preparation and HPLC separation approaches to speciation analysis of selenium in yeast by ICP-MS [J].
Casiot, C ;
Szpunar, J ;
Lobinski, R ;
Potin-Gautier, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) :645-650
[5]  
Clark LC, 1998, BRIT J UROL, V81, P730
[6]  
Combs GF, 1997, SELENIUM CANC PREVEN
[7]  
EBDON L, 2000, SPECIATION, V21, P1
[8]  
*EU MULSP PROJ, 1999, INT EX AG 1 2
[9]   Retention behavior of inorganic and organic selenium compounds on a silica-based strong-cation-exchange column with an inductively coupled plasma mass spectrometer as selenium-specific detector [J].
Goessler, W ;
Kuehnelt, D ;
Schlagenhaufen, C ;
Kalcher, K ;
Abegaz, M ;
Irgolic, KJ .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :233-245
[10]  
Gómez-Ariza JL, 1999, APPL ORGANOMET CHEM, V13, P783, DOI 10.1002/(SICI)1099-0739(199910)13:10<783::AID-AOC907>3.0.CO