Estimation of Free-Living Energy Expenditure Using a Novel Activity Monitor Designed to Minimize Obtrusiveness

被引:74
作者
Bonomi, Alberto G. [1 ,2 ]
Plasqui, Guy [1 ]
Goris, Annelies H. C. [3 ]
Westerterp, Klass R. [1 ]
机构
[1] Maastricht Univ, Dept Human Biol, Maastricht, Netherlands
[2] Philips Res Labs, Grp Care & Hlth Applicat, Eindhoven, Netherlands
[3] Philips New Wellness Solut, Lifestyle Incubator, Eindhoven, Netherlands
关键词
PHYSICAL-ACTIVITY; BODY-COMPOSITION; HEART-RATE; VALIDATION; ACCELEROMETERS; OVERWEIGHT; MOVEMENT; ADULTS;
D O I
10.1038/oby.2010.34
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to investigate the ability of a novel activity monitor designed to be minimally obtrusive in predicting free-living energy expenditure. Subjects were 18 men and 12 women (age: 41 +/- 11 years, BMI: 24.4 +/- 3 kg/m(2)). The habitual physical activity was monitored for 14 days using a DirectLife triaxial accelerometer for movement registration (Tracmor(D)) (Philips New Wellness Solutions, Lifestyle Incubator, the Netherlands). Tracmor(D) output was expressed as activity counts per day (Cnts/d). Simultaneously, total energy expenditure (TEE) was measured in free-living conditions using doubly labeled water (DLW). Activity energy expenditure (AEE) and the physical activity level (PAL) were determined from TEE and sleeping metabolic rate (SMR). A multiple-linear regression model predicted 76% of the variance in TEE, using as independent variables SMR (partial-r(2) = 0.55, P < 0.001), and Cnts/d (partial-r(2) = 0.21, P < 0.001). The s.e. of TEE estimates was 0.9 MJ/day or 7.4% of the average TEE. A model based on body mass (partial-r(2) = 0.31, P < 0.001) and Cnts/d (partial-r(2) = 0.23, P < 0.001) predicted 54% of the variance in TEE. Cnts/d were significantly and positively associated with AEE (r = 0.54, P < 0.01), PAL (r = 0.68, P < 0.001), and AEE corrected by body mass (r = 0.71, P < 0.001). This study showed that the Tracmor(D) is a highly accurate instrument for predicting free-living energy expenditure. The miniaturized design did not harm the ability of the instrument in measuring physical activity and in determining outcome parameters of physical activity such as TEE, AEE, and PAL.
引用
收藏
页码:1845 / 1851
页数:7
相关论文
共 32 条
[1]   Predicting Physical Activity Energy Expenditure Using Accelerometry in Adults From Sub-Sahara Africa [J].
Assah, Felix K. ;
Ekelund, Ulf ;
Brage, Soren ;
Corder, Kirsten ;
Wright, Antony ;
Mbanya, Jean C. ;
Wareham, Nicholas J. .
OBESITY, 2009, 17 (08) :1588-1595
[2]   Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer [J].
Bonomi, A. G. ;
Plasqui, G. ;
Goris, A. H. C. ;
Westerterp, K. R. .
JOURNAL OF APPLIED PHYSIOLOGY, 2009, 107 (03) :655-661
[3]   Detection of Type, Duration, and Intensity of Physical Activity Using an Accelerometer [J].
Bonomi, Alberto G. ;
Goris, Annelies H. C. ;
Yin, Bin ;
Westerterp, Klaas R. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (09) :1770-1777
[4]   Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living [J].
Brage, S ;
Brage, N ;
Ekelund, U ;
Luan, J ;
Franks, PW ;
Froberg, K ;
Wareham, NJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) :517-524
[5]   An investigation of a novel three-dimensional activity monitor to predict free-living energy expenditure [J].
Carter, James ;
Wilkinson, David ;
Blacker, Sam ;
Rayson, Mark ;
Bilzon, James ;
Izard, Rachel ;
Coward, Andy ;
Wright, Antony ;
Nevill, Alan ;
Rennie, Kirsten ;
Mccaffrey, Tracey ;
Livingstone, Barbara .
JOURNAL OF SPORTS SCIENCES, 2008, 26 (06) :553-561
[6]   Improving energy expenditure estimation by using a triaxial accelerometer [J].
Chen, KY ;
Sun, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (06) :2112-2122
[7]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500
[8]   A novel method for using accelerometer data to predict energy expenditure [J].
Crouter, SE ;
Clowers, KG ;
Bassett, DR .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (04) :1324-1331
[9]  
Ekelund U, 2004, AM J CLIN NUTR, V79, P851
[10]  
GORIS AH, 2008, PERSUASIVE 2008