New spectral imaging techniques for blood oximetry in the retina

被引:14
作者
Alabboud, Ied [1 ]
Muyo, Gonzalo [1 ]
Gorman, Alistair [1 ]
Mordant, David [1 ,2 ]
McNaught, Andrew [1 ,2 ]
Petres, Clement [1 ]
Petillot, Yvan R. [1 ]
Harvey, Andrew R. [1 ]
机构
[1] Heriot Watt Univ, Sch Engn & Phys Sci, Edinburgh EH14 4AS, Midlothian, Scotland
[2] Cheltenham Gen Hosp, Dept Ophthalmol, Cheltenham GL537AN, Glos, England
来源
NOVEL OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS III | 2007年 / 6631卷
关键词
blood oximetry; retinal imaging; spectral imaging;
D O I
10.1117/12.728535
中图分类号
O43 [光学];
学科分类号
070207 [光学]; 0803 [光学工程];
摘要
Hyperspectral imaging of the retina presents a unique opportunity for direct and quantitative mapping of retinal biochemistry - particularly of the vasculature where blood oximetry is enabled by the strong variation of absorption spectra with oxygenation. This is particularly pertinent both to research and to clinical investigation and diagnosis of retinal diseases such as diabetes, glaucoma and age-related macular degeneration. The optimal exploitation of hyperspectral imaging however, presents a set of challenging problems, including; the poorly characterised and controlled optical environment of structures within the retina to be imaged; the erratic motion of the eye ball; and the compounding effects of the optical sensitivity of the retina and the low numerical aperture of the eye. We have developed two spectral imaging techniques to address these issues. We describe first a system in which a liquid crystal tuneable filter is integrated into the illumination system of a conventional fundus camera to enable time-sequential, random access recording of narrow-band spectral images. Image processing techniques are described to eradicate the artefacts that may be introduced by time-sequential imaging. In addition we describe a unique snapshot spectral imaging technique dubbed IRIS that employs polarising interferometry and Wollaston prism beam splitters to simultaneously replicate and spectrally filter images of the retina into multiple spectral bands onto a single detector array. Results of early clinical trials acquired with these two techniques together with a physical model which enables oximetry map are reported.
引用
收藏
页数:10
相关论文
共 19 条
[1]
ALABBOUD I, 2007, ARVO ABSTR
[2]
ALONI EH, 2002, ARVO ABSTR
[3]
Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation [J].
Beach, JM ;
Schwenzer, KJ ;
Srinivas, S ;
Kim, D ;
Tiedeman, JS .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) :748-758
[4]
Chang C.-I., 2003, Hyperspectral Imaging: Techniques for Spectral Detection and Classification, V1
[5]
CIDECIYAN AV, 1995, IEEE ENG MED BIOL
[6]
NONINVASIVE TECHNIQUE FOR OXIMETRY OF BLOOD IN RETINAL-VESSELS [J].
DELORI, FC .
APPLIED OPTICS, 1988, 27 (06) :1113-1125
[7]
Demonstration of a high-speed nonscanning imaging spectrometer [J].
Descour, MR ;
Volin, CE ;
Dereniak, EL ;
Thome, KJ ;
Schumacher, AB ;
Wilson, DW ;
Maker, PD .
OPTICS LETTERS, 1997, 22 (16) :1271-1273
[8]
Imaging spectroscopy using tunable filters: A review [J].
Gat, N .
WAVELET APPLICATIONS VII, 2000, 4056 :50-64
[9]
Hammer M, 1997, J Biomed Opt, V2, P418, DOI 10.1117/12.285093
[10]
Automatic retinal oximetry [J].
Hardarson, Sveinn Hakon ;
Harris, Alon ;
Karlsson, Robert Arnar ;
Halldorsson, Gisli Hreinn ;
Kagemann, Larry ;
Rechtman, Ehud ;
Zoega, Gunnar Mar ;
Eysteinsson, Thor ;
Benediktsson, Jon Atli ;
Thorsteinsson, Adalbjorn ;
Jensen, Peter Koch ;
Beach, James ;
Stefansson, Einar .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) :5011-5016