Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase?

被引:50
作者
Barrett, T. [1 ]
Bowden, D. J.
Shaida, N.
Godfrey, E. M.
Taylor, A.
Lomas, D. J.
Shaw, A. S.
机构
[1] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 0QQ, England
关键词
Dual source CT; Dual energy; Virtual unenhanced; Liver; DETECTING HEPATOCELLULAR-CARCINOMA; ENERGY CT; CLINICAL-APPLICATIONS; MULTIDETECTOR CT; HELICAL CT; IMAGES; ABDOMEN;
D O I
10.1016/j.ejrad.2011.03.042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Introduction: Dual-energy dual source CT can almost simultaneously image patients using two different tube potentials, allowing material decomposition and creation of 'virtual unenhanced' (VU) images from post-contrast series. Methods: 75 patients undergoing triple-phase liver CT examinations were imaged using a second generation dual-source CT machine with tube potentials 140/100 kVp. Post-processing VU series were derived from arterial and portal phases. Regions-of-interest from liver parenchyma and within fat ('noise' assessment) were drawn to compare VU series to conventional unenhanced (CU) series. Subjective analysis assessed image quality and the suitability of VU to replace CU series. Results: Mean Hounsfield unit (HU) values of liver were higher in the VU series: portal 51.9 (SD = 10.29), arterial 51.1 (SD = 10.05), compared to the CU series 49.2 (SD = 9.11); P < 0.001. However, Pearson's correlation of the VU and CU series remained excellent: 0.838 (portal), 0.831 (arterial). Bland-Altman plots also showed good agreement between both VU and the CU datasets. Noise measurements were significantly lower in both VU series (P < 0.001). For subjective analysis, image quality was rated as very good/excellent in 100% of CU images, 93.3% of portal VU and 88.7% of arterial VU series. Overall, portal VU and arterial VU images were acceptable replacements for the CU series in 97.4% and 96.1%, respectively. Post-processing was noted to create a number of artefacts in VU images - knowledge of these is essential for interpretation. Conclusions: Portal and arterial-derived VU images objectively correlate to CU images and demonstrate good image quality and acceptability. VU image sets could replace the conventional unenhanced images in the vast majority of cases, significantly reducing radiation dose. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1438 / 1445
页数:8
相关论文
共 22 条
[1]
ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]
Renal Stone Assessment with Dual-Energy Multidetector CT and Advanced Postprocessing Techniques: Improved Characterization of Renal Stone Composition-Pilot Study [J].
Boll, Daniel T. ;
Patil, Neil A. ;
Paulson, Erik K. ;
Merkle, Elmar M. ;
Simmons, W. Neal ;
Pierre, Sean A. ;
Preminger, Glenn M. .
RADIOLOGY, 2009, 250 (03) :813-820
[3]
Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images [J].
De Cecco, Carlo Nicola ;
Buffa, Vitaliano ;
Fedeli, Stefano ;
Luzietti, Monica ;
Vallone, Andrea ;
Ruopoli, Roberto ;
Miele, Vittorio ;
Rengo, Marco ;
Paolantonio, Pasquale ;
Enrici, Michelangelo Maurizi ;
Laghi, Andrea ;
David, Vincenzo .
EUROPEAN RADIOLOGY, 2010, 20 (12) :2870-2875
[4]
Fleiss JL., 1981, STAT METHODS RATES P
[5]
Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440
[6]
Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[7]
Hepatocellular carcinoma: Role of unenhanced and delayed phase multi-detector row helical CT in patients with cirrhosis [J].
Iannaccone, R ;
Laghi, A ;
Catalano, C ;
Rossi, P ;
Mangiapane, F ;
Murakami, T ;
Hori, M ;
Piacentini, F ;
Nofroni, I ;
Passariello, R .
RADIOLOGY, 2005, 234 (02) :460-467
[8]
Focal Iodine Defects on Color-Coded Iodine Perfusion Maps of Dual-Energy Pulmonary CT Angiography Images: A Potential Diagnostic Pitfall [J].
Kang, Mi-Jin ;
Park, Chang Min ;
Lee, Chang-Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :W325-W330
[9]
Dual-energy CT revisited with multidetector CT: review of principles and clinical applications [J].
Karcaaltincaba, Musturay ;
Aktas, Aykut .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2011, 17 (03) :181-194
[10]
Optimal phases of dynamic CT for detecting hepatocellular carcinoma: evaluation of unenhanced and triple-phase images [J].
Kim, T ;
Murakami, T ;
Takahashi, S ;
Tsuda, K ;
Tomoda, K ;
Narumi, Y ;
Oi, H ;
Sakon, M ;
Nakamura, H .
ABDOMINAL IMAGING, 1999, 24 (05) :473-480