Initial experience with sutureless proximal anastomoses performed with a mechanical connector leading to clampless off-pump coronary artery bypass surgery

被引:19
作者
Katariya, K [1 ]
Yassin, S [1 ]
Tehrani, HY [1 ]
Lombardi, P [1 ]
Masroor, S [1 ]
Salerno, TA [1 ]
机构
[1] Univ Miami, Jackson Mem Hosp, Div Cardiothorac Surg, Miami, FL 33136 USA
关键词
D O I
10.1016/S0003-4975(03)01587-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We report our early experience with the Symmetry Aortic Connector (St. Jude Medical, St. Paul, MN) used for sutureless proximal aortosaphenous vein graft anastomoses without any cross clamp during coronary bypass procedures. Methods. Between November 2001 and August 2002, 206 saphenous vein to aorta proximal anastomoses were created in 132 patients using the Symmetry device. All procedures were performed as part of off-pump coronary artery bypass surgery without any aortic clamping. Intraoperative variables and postoperative data were collected and analyzed retrospectively. Results. All 206 anastomoses (100%) were successfully completed with the connector. Severe atherosclerotic disease of the aorta was documented in 16 patients (12%). Four anastomoses (2%) required additional suture placement. Predeployment problems occurred with 3 grafts (2.5%) during loading of the connector. Average number of distal bypasses was 3.2 per patient. One patient (0.7%) required reoperation for bleeding from a proximal anastomosis. Six patients (4.5%) had perioperative myocardial infarction documented by electrocardiographic changes. Thirty-day operative mortality was 3% (4 patients). Intraoperative transit time flow measurement was performed in all cases (100%). Postoperative angiography in 43 patients at a median 3 months postoperatively revealed occlusion of 9 of the 81 saphenous vein grafts (11%). Conclusions. The initial experience with a proximal saphenous vein graft to aorta anastomosis using the Symmetry connector demonstrates safety and ease of use. There is however some concern with early graft closure. A prospective randomized study is needed to clarify these concerns. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:563 / 567
页数:5
相关论文
共 12 条
[1]  
ANDROSOV PI, 1956, ARCH SURG-CHICAGO, V73, P902
[2]   Aortic atheromatosis and risks of cerebral embolization [J].
Barbut, D ;
Gold, JP .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (01) :24-30
[3]  
BREUER A, 1981, STROKE, V11, P1136
[4]  
Buffolo E, 2001, BEATING HEART CORONARY ARTERY SURGERY, P3
[5]   Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta [J].
Calafiore, AM ;
Bar-El, Y ;
Vitolla, G ;
Di Giammarco, G ;
Teodori, G ;
Iacò, AL ;
D'Alessandro, S ;
Di Mauro, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (05) :854-858
[6]  
Carrel A., 1902, LYON MED, V98, P859
[7]   Minimizing aortic manipulation during OPCAB using the symmetry aortic connector system for proximal vein graft anastomoses [J].
Eckstein, FS ;
Bonilla, LF ;
Englberger, L ;
Stauffer, E ;
Berg, TA ;
Schmidli, J ;
Carrel, TP .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :S995-S998
[8]   Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 years [J].
FitzGibbon, GM ;
Kafka, HP ;
Leach, AJ ;
Keon, WJ ;
Hooper, GD ;
Burton, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (03) :616-626
[9]   Risk factors for early or delayed stroke after cardiac surgery [J].
Hogue, CW ;
Murphy, SF ;
Schechtman, KB ;
Dávila-Román, VG .
CIRCULATION, 1999, 100 (06) :642-647
[10]   Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts [J].
Kim, KB ;
Lim, C ;
Lee, C ;
Chae, IH ;
Oh, BH ;
Lee, MM ;
Park, YB .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :S1033-S1037