The evolutionary state of electrosurgery: where are we now?

被引:39
作者
Advincula, Arnold P. [1 ]
Wang, Karen [1 ]
机构
[1] Univ Michigan, Ctr Med, Dept Obstet & Gynecol, L Womens Hosp 4000, Ann Arbor, MI 48109 USA
关键词
bipolar; electrosurgery; hemostasis; monopolar;
D O I
10.1097/GCO.0b013e3283073ab7
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose of review The purpose of this review is to discuss the evolutionary changes that have taken place in the area of electrosurgery. The distinct differences between devices along with disadvantages and ways of minimizing hazards will be analyzed. Recent findings Since the first surgical application of electricity in the 1880s, the use of radiofrequency current in surgery has grown. Although monopolar and bipolar energy form the backbone of electrosurgery, various modifications have been made to both the electrosurgical generators and the hand instruments. Much of the driving force behind these modifications has been the goal of minimizing possible complications while improving surgical efficiency. Recently, the ability to obtain vessel sealing has dramatically impacted clinical practice in open, laparoscopic, and vaginal surgery. Summary Current evidence demonstrates the effectiveness and safety of electrosurgical devices in gynecologic surgery. Technology has evolved to allow vessel sealing capability through various instruments. Critical to the successful use of these advanced electrosurgical devices is a thorough understanding of their individual differences and nuances in order to obtain the desired tissue effects. Further studies are needed to determine the most appropriate applications and surgical procedures for these devices.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 30 条
[1]   Bipolar electrosurgery: Convention and innovation [J].
Brill, Andrew I. .
CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01) :153-158
[2]   History of bipolar coagulation [J].
Bulsara, KR ;
Sukhla, S ;
Nimjee, SM .
NEUROSURGICAL REVIEW, 2006, 29 (02) :93-96
[3]   Real-time thermography during energized vessel sealing and dissection [J].
Campbell, PA ;
Cresswell, AB ;
Frank, TG ;
Cuschieri, A .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (10) :1640-1645
[4]   A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries [J].
Carbonell, AM ;
Joels, CS ;
Kercher, KW ;
Matthews, BD ;
Sing, RF ;
Heniford, BT .
JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES-PART A, 2003, 13 (06) :377-380
[5]   Painless vaginal hysterectomy with thermal hemostasis (results of a series of 152 cases) [J].
Clave, H. ;
Baar, H. ;
Niccolai, P. .
GYNECOLOGICAL SURGERY, 2005, 2 (02) :101-105
[6]   Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries [J].
Harold, KL ;
Pollinger, H ;
Matthews, BD ;
Kercher, KW ;
Sing, RF ;
Heniford, BT .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (08) :1228-1230
[7]   Initial results with an electrothermal bipolar vessel sealer [J].
Heniford, BT ;
Matthews, BD ;
Sing, RF ;
Backus, C ;
Pratt, B ;
Greene, FL .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (08) :799-801
[8]  
JONES CM, 2006, ELECTROSURGERY CURR, V63, P458
[9]   Complications of laparoscopic pelvic surgery: recognition, management and prevention [J].
Li, TC ;
Saravelos, H ;
Richmond, M ;
Cooke, ID .
HUMAN REPRODUCTION UPDATE, 1997, 3 (05) :505-515
[10]   Electrosurgery - Technical note [J].
Malis, LI .
JOURNAL OF NEUROSURGERY, 1996, 85 (05) :970-975