Carotid plaque characterization by duplex scanning - Observer error may undermine current clinical trials

被引:82
作者
Arnold, JAC
Modaresi, KB
Thomas, N
Taylor, PR
Padayachee, TS
机构
[1] Univ London Kings Coll, Dept Radiol Sci, Ultrason Angiol Lab, London WC2R 2LS, England
[2] Univ London Kings Coll, Dept Surg, London WC2R 2LS, England
关键词
atherosclerosis; carotid stenosis; ultrasonography; Doppler; duplex;
D O I
10.1161/01.STR.30.1.61
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Clinical studies currently in progress are using subjective methods to characterize plaque morphology from ultrasound images. However, there are few studies on the intraobserver and interobserver variability of these classifications. This study was designed to assess these variables. Methods-Grading of plaque morphology from ultrasound images, stored both digitally and to hard copy, was performed by 2 classification schemes. Interobserver agreement was determined by 4 observers. Within-observer agreement was performed at intervals for up to 6 months. Accuracy of the 2 methods was determined by comparison with histology. Results-Within- and between-observer agreement was moderate to good for full-color digital image analyses, with pooled kappa values of kappa(p) = 0.49 +/- 0.10 and kappa(p) = 0.62 +/- 0.07 for the 2-category method and kappa(p) = 0.53 +/- 0.06 and kappa(p) = 0.52 +/- 0.05 for the 4-category method, respectively. Hard copy data analyses gave lower kappa values. The more experienced observers produced higher within-observer agreements and higher correlation with histology. Conclusions-Reproducible grading of ultrasound images is not consistently achievable among experienced observers, and within-observer agreement may vary with time. The current subjective ultrasound characterization of carotid plaque morphology used in clinical trials may be associated with unacceptable levels of reproducibility in some centers. Variability between observers may be reduced by using the simpler 2-category grading of plaque morphology to interrogate full-color digitally stored images. Observer agreement should be audited regularly.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 23 条
[1]   SONOGRAPHIC CHARACTERIZATION OF CAROTID PLAQUE - DETECTION OF HEMORRHAGE [J].
BLUTH, EI ;
KAY, D ;
MERRITT, CRB ;
SULLIVAN, M ;
FARR, G ;
MILLS, NL ;
FOREMAN, M ;
SLOAN, K ;
SCHLATER, M ;
STEWART, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (05) :1061-1065
[2]  
BOCK RW, 1992, DIAGNOSTIC VASCULAR, V21, P254
[3]   Atherosclerotic plaque rupture in symptomatic carotid artery stenosis [J].
Carr, S ;
Farb, A ;
Pearce, WH ;
Virmani, R ;
Yao, JST .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (05) :755-765
[4]   ACCURACY AND PROGNOSTIC CONSEQUENCES OF ULTRASONOGRAPHY IN IDENTIFYING SEVERE CAROTID-ARTERY STENOSIS [J].
ELIASZIW, M ;
RANKIN, RN ;
FOX, AJ ;
HAYNES, RB ;
BARNETT, HJM .
STROKE, 1995, 26 (10) :1747-1752
[5]  
*EUR CAR PLAQ STUD, 1995, J VASC ENDOVASC SURG, V10, P23
[6]  
FALK E, 1992, CIRCULATION, V86, P30
[7]  
Fleiss JL, 1981, STAT METHODS RATES P
[8]  
FUSTER V, 1990, CIRCULATION, V82, P47
[9]   CHARACTERIZATION OF SYMPTOMATIC AND ASYMPTOMATIC CAROTID PLAQUES USING HIGH-RESOLUTION REAL-TIME ULTRASONOGRAPHY [J].
GEROULAKOS, G ;
RAMASWAMI, G ;
NICOLAIDES, A ;
JAMES, K ;
LABROPOULOS, N ;
BELCARO, G ;
HOLLOWAY, M .
BRITISH JOURNAL OF SURGERY, 1993, 80 (10) :1274-1277
[10]  
GRAYWEALE AC, 1988, J CARDIOVASC SURG, V29, P676