Impact of temperature and humidity on the perception of indoor air quality

被引:375
作者
Fang, L [1 ]
Clausen, G [1 ]
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Dept Energy Engn, Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
来源
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE | 1998年 / 8卷 / 02期
关键词
indoor air quality; perceived air quality; temperature; humidity; perception; ventilation;
D O I
10.1111/j.1600-0668.1998.t01-2-00003.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Sensory responses to clean air and air polluted by five building materials under different combinations of temperature and humidity in the ranges 18-28 degrees C and 30-70%RH were studied in the laboratory. A specially designed test system was built and a set of experiments was designed to observe separately the impact of temperature and humidity on the perception of air quality/odour intensity, and on the emission of pollutants from the materials. This paper reports on the impact on perception. The odour intensity of air did not change significantly with temperature and humidity; however, a strong and significant impact of temperature and humidity on the perception of air quality was found. The air was perceived as less acceptable with increasing temperature and humidity. This impact decreased with an increasing level of air pollution. Significant linear correlations were found between acceptability and enthalpy of the air at all pollution levels tested, and a linear model was established to describe the dependence of perceived air quality on temperature and humidity at different pollution levels. (C) Indoor Air (1998).
引用
收藏
页码:80 / 90
页数:11
相关论文
共 25 条
  • [1] ALBRECHTSEN O, 1988, P HLTH BUILD 88 STOC, V3, P25
  • [2] INDOOR AIR-POLLUTION DUE TO CHIPBOARD USED AS A CONSTRUCTION MATERIAL
    ANDERSEN, I
    LUNDQVIST, GR
    MOLHAVE, L
    [J]. ATMOSPHERIC ENVIRONMENT, 1975, 9 (12) : 1121 - 1127
  • [3] *ASHRAE, 1989, 621989 ASHRAE
  • [4] Berg-Munch B., 1982, ENVIRON INT, V8, P333, DOI DOI 10.1016/0160-4120(82)90046-0
  • [5] BERGLUND L, 1989, P IAQ 89 HUM EQ HLTH, P93
  • [6] BLUYSSEN PM, 1996, P IND AIR 96 NAG 7 2, V3, P619
  • [7] BREMER J, 1993, P 6 INT C IND AIR QU, V2, P419
  • [8] VENTILATION REQUIREMENTS IN BUILDINGS .1. CONTROL OF OCCUPANCY ODOR AND TOBACCO-SMOKE ODOR
    CAIN, WS
    LEADERER, BP
    ISSEROFF, R
    BERGLUND, LG
    HUEY, RJ
    LIPSITT, ED
    PERLMAN, D
    [J]. ATMOSPHERIC ENVIRONMENT, 1983, 17 (06) : 1183 - 1197
  • [9] CLAUSEN GH, 1985, P CLIMA 2000 COP, V4, P345
  • [10] *DIN, 1994, 1946 DIN