The effect of bispectral index monitoring on anesthetic use and recovery in children anesthetized with sevoflurane in nitrous oxide

被引:37
作者
Bannister, CF
Brosius, KK
Sigl, JC
Meyer, BJ
Sebel, PS
机构
[1] Emory Univ, Sch Med, Childrens Healthcare Atlanta, Dept Anesthesiol, Atlanta, GA 30322 USA
[2] Aspect Med Syst, Newton, MA USA
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
The utility of bispectral index (BIS) monitoring to guide anesthetic administration has been demonstrated in adults. This prospective, randomized observer-blinded study was designed to evaluate the effect of BIS monitoring on anesthetic use and recovery characteristics in pediatric patients. After data collection in 38 historical controls, 202 patients age 0-18 yr were randomized into one of two groups: standard practice (SP) and BIS guided (BIS). Patients age 0-3 yr undergoing inguinal hernia repair (III) and patients age 3-18 yr undergoing tonsillectomy and/or adenoidectomy (TA) were selected. All patients were anesthetized with sevoflurane in 60% N2O/O-2. Hernia patients also received a caudal epidural anesthetic before surgery. In the BIS group, anesthetic delivery was adjusted in an effort to achieve a target BIS of 45-60 during maintenance and 60-70 during the last 15 min of the procedure. BIS was recorded throughout surgery in all patients, but data were unavailable to the anesthesiologist in the SP group. In the TA patients, BIS monitoring was associated with a significant reduction in end-tidal sevoflurane concentration during maintenance (2.4 +/- 0.6%, SP and 1.8 +/- 0.4% BIS, mean +/- SD) and during the last 15 min of the procedure (2.1 +/- 0.7, SP and 1.6 +/- 0.6, BIS). There was a 25%-40% decrease in measured recovery times. In the patients 0-6 mo of age undergoing IH, sevoflurane concentrations during maintenance (2.0 +/- 0.4% SP, 0.9 +/- 0.8 BIS), during the last 15 min (1.6 +/- 0.4% SP, 0.6 +/- 0.6% BIS), and at the end of the procedure (1.1 +/- 0.6% SP, 0.3 +/- 0.3% BIS) were smaller in the BIS group. Emergence and recovery measures were unaffected by BIS titration. In the children 6 mo-3 yr of age, there were no significant differences between the SP and BIS groups in anesthetic use or recovery measures.
引用
收藏
页码:877 / 881
页数:5
相关论文
共 16 条
[1]
THE POSTANESTHESIA RECOVERY SCORE REVISITED [J].
ALDRETE, JA .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (01) :89-91
[2]
Pediatric evaluation of the bispectral index (BIS) monitor and correlation of BIS with end-tidal sevoflurane concentration in infants and children [J].
Denman, WT ;
Swanson, EL ;
Rosow, D ;
Ezbicki, K ;
Connors, PD ;
Rosow, CE .
ANESTHESIA AND ANALGESIA, 2000, 90 (04) :872-877
[3]
Recovery of consciousness after thiopental or propofol - Bispectral index and the isolated forearm technique [J].
Flaishon, R ;
Windsor, A ;
Sigl, J ;
Sebel, PS .
ANESTHESIOLOGY, 1997, 86 (03) :613-619
[4]
Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[5]
Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[6]
Guinard JP, 1998, ANESTHESIOLOGY, V89, pA104
[7]
PROGNOSTIC VALUE OF BACKGROUND PATTERNS IN THE NEONATAL EEG [J].
HOLMES, GL ;
LOMBROSO, CT .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1993, 10 (03) :323-352
[8]
Electroencephalographic derivatives as a tool for predicting the depth of sedation and anesthesia induced by sevoflurane [J].
Katoh, T ;
Suzuki, A ;
Ikeda, K .
ANESTHESIOLOGY, 1998, 88 (03) :642-650
[9]
PEDIATRIC NEURAXIAL BLOCKADE [J].
PULLERITS, J ;
HOLZMAN, RS .
JOURNAL OF CLINICAL ANESTHESIA, 1993, 5 (04) :342-354
[10]
A primer for EEG signal processing in anesthesia [J].
Rampil, IJ .
ANESTHESIOLOGY, 1998, 89 (04) :980-1002