Kinematics of mobile-bearing unicompartmental knee arthroplasty compared to native: results from an in vitro study

被引:42
作者
Peersman, Geert [1 ,2 ]
Slane, Josh [1 ]
Vuylsteke, Philippe [2 ]
Fuchs-Winkelmann, Susanne [3 ]
Dworschak, Philipp [3 ]
Heyse, Thomas [3 ]
Scheys, Lennart [1 ]
机构
[1] Katholieke Univ Leuven, Inst Orthopaed Res & Training, Campus Pellenberg, Louvain, Belgium
[2] Ziekenhuis Netwerk Antwerp, Dept Orthopaed Surg, Campus Stuivenberg, Antwerp, Belgium
[3] Univ Hosp Marburg, Ctr Orthoped & Trauma Surg, Marburg, Germany
关键词
Knee kinematics; Unicondylar knee arthroplasty; Mobile-bearing; Biomechanics; UKA; REPLACEMENT; UNICONDYLAR; STABILITY; OUTCOMES; SYSTEM; FORCE;
D O I
10.1007/s00402-017-2794-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Fixed-bearing unicompartmental knee arthroplasty (UKA) closely replicates native knee kinematics. As few studies have assessed kinematics following mobile-bearing (MB) UKA, the current study aimed to investigate whether MB UKA preserves natural knee kinematics. Seven fresh-frozen full-leg cadaver specimens were prepared and mounted in a kinematic rig that allowed all degrees of freedom at the knee. Three motion patterns, passive flexion-extension (0A degrees-110A degrees flexion), open-chain extension (5A degrees-70A degrees flexion) and squatting (30A degrees-100A degrees flexion), were performed pre- and post-implantation of a medial MB UKA and compared in terms of rotational and translational knee joint kinematics in the different anatomical planes, respectively. In terms of frontal plane rotational kinematics, MB UKA specimens were in a more valgus orientation for all motion patterns. In the axial plane, internal rotation of the tibia before and after UKA was consistent, regardless of motion task, with no significant differences. In terms of frontal plane, i.e., inferior-superior, translations, the FMCC was significantly higher in UKA knees in all flexion angles and motor tasks, except in early flexion during passive motion. In terms of axial plane, i.e., anteroposterior (AP), translations, during open-chain activities, the femoral medial condyle center (FMCC) tended to be more posterior following UKA relative to the native knee in mid-flexion and above. AP excursions of the FMCC were small in all tested motions, however. There was substantial AP translation of the femoral lateral condyle center during passive motion before and after UKA, which was significantly different for flexion angles > 38A degrees. Our study data demonstrate that the kinematics of the unloaded knee following MB UKA closely resemble those of the native knee while relative medial overstuffing with UKA will result in the joint being more valgus. However, replacing the conforming and rigidly fixed medial meniscus with a mobile inlay may successfully prevent aberrant posterior translation of the medial femoral compartment during passive motion and squatting motion.
引用
收藏
页码:1557 / 1563
页数:7
相关论文
共 29 条
[1]
In vivo determination of knee kinematics for subjects implanted with a unicompartmental arthroplasty [J].
Argenson, JNA ;
Komistek, RD ;
Aubaniac, JM ;
Dennis, DA ;
Northcut, EJ ;
Anderson, DT ;
Agostini, S .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1049-1054
[2]
Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system [J].
Becker, Roland ;
Mauer, Christian ;
Staerke, Christian ;
Brosz, Mathias ;
Zantop, Thore ;
Lohmann, Christoph H. ;
Schulze, Martin .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (11) :2427-2432
[3]
Effect of Calibration Method on Tekscan Sensor Accuracy [J].
Brimacombe, Jill M. ;
Wilson, David R. ;
Hodgson, Antony J. ;
Ho, Karen C. T. ;
Anglin, Carolyn .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03)
[4]
Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs [J].
Catani, Fabio ;
Benedetti, Maria Grazia ;
Bianchi, Luca ;
Marchionni, Valentina ;
Giannini, Sandro ;
Leardini, Alberto .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (06) :1042-1048
[5]
Comparison of a mobile with a fixed-bearing unicompartmental knee implant [J].
Emerson, RH ;
Hansborough, T ;
Reitman, RA ;
Rosenfeldt, W ;
Higgins, LL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :62-70
[6]
In vitro kinematics of fixed versus mobile bearing in unicondylar knee arthroplasty [J].
Ettinger, Max ;
Zoch, Johanna Marie ;
Becher, Christoph ;
Hurschler, Christof ;
Stukenborg-Colsman, Christina ;
Claassen, Leif ;
Ostermeier, Sven ;
Calliess, Tilman .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (06) :871-877
[7]
Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study [J].
Gleeson, RE ;
Evans, R ;
Ackroyd, CE ;
Webb, J ;
Newman, JH .
KNEE, 2004, 11 (05) :379-384
[8]
A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[9]
Balancing UKA: overstuffing leads to high medial collateral ligament strains [J].
Heyse, Thomas J. ;
El-Zayat, Bilal F. ;
De Corte, Ronny ;
Scheys, Lennart ;
Chevalier, Yan ;
Fuchs-Winkelmann, Susanne ;
Labey, Luc .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (10) :3218-3228
[10]
Frontal plane stability following UKA in a biomechanical study [J].
Heyse, Thomas J. ;
Tucker, Scott M. ;
Rajak, Yogesh ;
Kia, Mohammad ;
Lipman, Joseph D. ;
Imhauser, Carl W. ;
Westrich, Geoffrey H. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (06) :857-865