Wide-Area Monitoring, Protection, and Control of Future Electric Power Networks

被引:521
作者
Terzija, Vladimir [1 ]
Valverde, Gustavo [1 ]
Cai, Deyu [1 ]
Regulski, Pawel [1 ]
Madani, Vahid [2 ]
Fitch, John [3 ]
Skok, Srdjan [4 ]
Begovic, Miroslav M. [5 ]
Phadke, Arun [6 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester M60 1QD, Lancs, England
[2] Pacific Gas & Elect Co, Oakland, CA 94612 USA
[3] Natl Grid, Asset Management, Warwick CV34 6DA, England
[4] Univ Rijeka, Fac Engn, Rijeka 51000, Croatia
[5] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[6] Virginia Polytech Univ, Dept Elect & Comp Engn, Blacksburg, VA 24061 USA
基金
英国工程与自然科学研究理事会;
关键词
Phasor measurement units (PMUs); synchronized measurement technology (SMT); wide-area monitoring; protection; and control (WAMPAC);
D O I
10.1109/JPROC.2010.2060450
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wide-area monitoring, protection, and control (WAMPAC) involves the use of system-wide information and the communication of selected local information to a remote location to counteract the propagation of large disturbances. Synchronized measurement technology (SMT) is an important element and enabler of WAMPAC. It is expected that WAMPAC systems will in the future reduce the number of catastrophic blackouts and generally improve the reliability and security of energy production, transmission, and distribution, particularly in power networks with a high level of operational uncertainties. In this paper, the technological and application issues are addressed. Several key monitoring, protection, and control applications are described and discussed. A strategy for developing a WAMPAC system in the United Kingdom is given as well.
引用
收藏
页码:80 / 93
页数:14
相关论文
共 24 条
[1]  
[Anonymous], PHASOR DATA REQUIREM
[2]   Measurements Get Together [J].
Chakrabarti, Saikat ;
Kyriakides, Elias ;
Bi, Tianshu ;
Cai, Deyu ;
Terzija, Vladimir .
IEEE POWER & ENERGY MAGAZINE, 2009, 7 (01) :41-49
[3]   Measurement-based dynamic load models: Derivation, comparison, and validation [J].
Choi, Byoung-Kon ;
Chiang, Hsiao-Dong ;
Li, Yinhong ;
Li, Hua ;
Chen, Yung-Tien ;
Huang, Der-Hua ;
Lauby, Mark G. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (03) :1276-1283
[4]  
KOSTEREV D, 2008, P IEEE PES GEN M PIT, DOI DOI 10.1109/PES.2008.4596557
[5]   Model validation for the August 10, 1996 WSCC system outage [J].
Kosterev, DN ;
Taylor, CW ;
Mittelstadt, WA .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (03) :967-974
[6]   On-line estimation of synchronous generator parameters using a damper current observer and a Graphic User Interface [J].
Kyriakides, E ;
Heydt, GI ;
Vittal, V .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (03) :499-507
[7]   Measurement-based load modeling using genetic algorithms [J].
Ma, Jin ;
Dong, Zhao-yang ;
He, Ren-mu ;
Hill, David J. .
2007 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION, VOLS 1-10, PROCEEDINGS, 2007, :2909-+
[8]  
MADANI V, 2007, P IREP S BULK POW SY, DOI DOI 10.1109/IREP.2007.4410559
[9]  
Madani V., 2009, GLOBAL IND EXPERIENC
[10]  
MUSTAFA MA, 2009, P IEEE POW EN SOC GE, DOI DOI 10.1109/PES.2009.5275200