Immediate and early implant loading protocols: A literature review of clinical studies

被引:211
作者
Attard, NJ [1 ]
Zarb, GA
机构
[1] Univ Malta, Dept Restorat Dent, Fac Dent Surg, Sch Med, Msida MSD 08, Malta
[2] Univ Toronto, Fac Dent, Dept Prosthodont, Toronto, ON, Canada
关键词
D O I
10.1016/j.prosdent.2005.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The purpose of this literature review is to present the outcomes of clinical studies oil immediate and early loading protocols, identify shortcomings, and suggest a number of questions that still require exploration. English language clinical studies, limited to peer-reviewed journals between 1975 and 2004, were reviewed to identify treatment outcomes with these loading protocols. The data were tabulated from studies reporting on patients treated with fixed and overdenture prostheses. The former included partially edentulous patients treated with single or multi-unit prostheses. Within the limitations of this review, it can be concluded that these treatment protocols are predictable in the anterior mandible, irrespective of implant type, surface topography, and prosthesis design (success rates 90%-100%). Limited evidence for the edentulous maxilla (success rates 90%-100%) and the partially edentulous patient (success rates 93%-100%) are available, underscoring the need for further research. Studies suggest that to achieve predictable results in extraction sites, implant placement should be restricted to sites without a history of periodontal involvement (success rates 61%-100%). A number of questions require further exploration. There is a need to thoroughly investigate clinical outcomes to measure the economic benefit of these protocols and the impact of treatment on a patient's quality of life. Furthermore, more accurate long-term studies reporting on treatment protocols for separate clinical situations are required to allow meaningful comparisons.
引用
收藏
页码:242 / 258
页数:17
相关论文
共 129 条
[1]
Adrianssens P, 2001, APPL OSSEOINTEGRATIO, V2, P17
[2]
Aires Ian, 2002, Implant Dent, V11, P87
[3]
Albrektsson T, 1998, INT J PROSTHODONT, V11, P517
[4]
DIRECT BONE ANCHORAGE OF DENTAL IMPLANTS [J].
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (02) :255-261
[5]
Albrektsson T., 1995, COLOR ATLAS TEXT DEN, P9
[6]
Immediate loading of single-tooth ITI implants in the anterior maxilla:: a prospective 5-year pilot study [J].
Andersen, E ;
Haanæs, HR ;
Knutsen, BM .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :281-287
[7]
Aparicio Carlos, 2003, Clin Implant Dent Relat Res, V5, P57, DOI 10.1111/j.1708-8208.2003.tb00183.x
[8]
TITANIUM PLASMA-SPRAYED (TPS) SCREW IMPLANTS FOR THE RECONSTRUCTION OF THE EDENTULOUS MANDIBLE [J].
BABBUSH, CA ;
KENT, JN ;
MISIEK, DJ .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1986, 44 (04) :274-282
[9]
Balshi T J, 1997, Implant Dent, V6, P83, DOI 10.1097/00008505-199700620-00002
[10]
Becker W, 1997, INT J ORAL MAX IMPL, V12, P454