Nonlinear and linear propagation of diagnostic ultrasound pulses

被引:23
作者
Filipczynski, L [1 ]
Kujawska, T [1 ]
Tymkiewicz, R [1 ]
Wójcik, J [1 ]
机构
[1] Polish Acad Sci, Inst Fundamental Technol Res, Dept Ultrasound, PL-00049 Warsaw, Poland
关键词
ultrasound; pulses; nonlinear propagation; diagnostics;
D O I
10.1016/S0301-5629(98)00174-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effect of nonlinear propagation in fluid followed by soft tissue was studied both theoretically and experimentally for a most crucial case in obstetrical ultrasonography. For this purpose, short pressure pulses, with the duration time of 1.3 mu s and a carrier frequency of 3 MHz, radiated by a concave transducer into water, with maximum intensities up to the value of 18 W/cm(2), were computed and measured. The ultrasonic beam had the physical focus at the distance of 6.5 cm, where the highest focal intensity of I-SPPA = 242 W/cm(2) was obtained. In front of the transducer, at a distance of 7 cm, artificial tissue samples prepared on the basis of ground porcine kidney, with a thickness of 0.5, 1.5 and 3 cm, were placed in water. Pressure pulses and their spectral components were produced numerically and measured by means of a PVDF hydrophone in water before and after penetrating the tissue samples. The theoretical analysis and measurements were carried out, in every case, for two signal levels: for a high level assuring nonlinear propagation and for a low one where conditions of linear propagation were fulfilled. In this way, it was possible to compare directly the effects of nonlinear and linear propagation, in every case showing a good conformity of theoretical values with measured ones. A method of determination of the effective frequency response of the hydrophone was elaborated to enable quantitative comparisons of numerical and experimental results. The theoretical part of our study was based on a paper of Wojcik (1998), enabling us to compute the characteristic function of nonlinear increase of absorption. An agreement of up to 10% was obtained when comparing theoretical and measured values of these functions in the investigated beam in water and behind tissue samples. The results obtained showed that the recently given theory of nonlinear absorption, based on the spectral analysis and the elaborated numerical procedures, may be useful in various practical ultrasonic medical problems and also in technological applications. (C) 1999 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:285 / 299
页数:15
相关论文
共 20 条
[1]   DISTORTION AND HARMONIC-GENERATION IN THE NEARFIELD OF A FINITE-AMPLITUDE SOUND BEAM [J].
AANONSEN, SI ;
BARKVE, T ;
TJOTTA, JN ;
TJOTTA, S .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1984, 75 (03) :749-768
[2]   INCREASED HEATING BY DIAGNOSTIC ULTRASOUND DUE TO NONLINEAR PROPAGATION [J].
BACON, DR ;
CARSTENSEN, EL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (01) :26-34
[3]  
BAMBER J C, 1979, Ultrasound in Medicine and Biology, V5, P149, DOI 10.1016/0301-5629(79)90083-8
[4]  
BRENDEL K, 1975, ACUSTICA, V32, P110
[5]  
BRIGGS A, 1992, ACOUSTIC MICROSCOPY, P35
[6]  
CARSTENSEN EL, 1982, ACUSTICA, V51, P116
[7]   NEW APPROACHES TO NONLINEAR DIFFRACTIVE FIELD PROPAGATION [J].
CHRISTOPHER, PT ;
PARKER, KJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (01) :488-499
[8]   NEW APPROACHES TO THE LINEAR PROPAGATION OF ACOUSTIC FIELDS [J].
CHRISTOPHER, PT ;
PARKER, KJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (01) :507-521
[9]   Finite amplitude distortion and its relationship to linear derating formulae for diagnostic ultrasound systems [J].
Christopher, T ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :1103-1116
[10]   EFFECTS OF PULSED ULTRASOUND ON THE FROG-HEART .2. AN INVESTIGATION OF HEATING AS A POTENTIAL MECHANISM [J].
DALECKI, D ;
RAEMAN, CH ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (05) :391-398